DOUBLE INSULATION
Double insulation is a concept in safety in electric power
tools, which eliminates the need for the usual three-wire
grounded power cord. All exposed metal parts are isolated
from the internal metal motor components with protecting
insulation. Double insulated tools do not need to be
grounded.
WARNING:
The double insulated system is intended to protect
the user from shock resulting from a break in the tool's
internal insulation. Observe all normal safety precautions
to avoid electrical shock.
NOTE: Servicing of a product with double insulation requires
extreme care and knowledge of the system and should
be performed only by a qualified service technician. For
service, we suggest you return the tool to your nearest
authorized service center for repair. Always use original
factory replacement parts when servicing.
ELECTRICAL CONNECTION
This product has a precision-built electric motor. It should be
connected to a power supply that is nominal 120V/60Hz
AC (typical U.S. household circuit). Do not operate this
product on direct current (DC). A substantial voltage drop
will cause a loss of power and the motor will overheat. If
your product does not operate when plugged into an outlet,
double-check the power supply.
GFCI
Ground Fault Circuit Interrupter (GFCI) protection should
be provided on the circuit(s) or outlet(s) to be used for the
product. Receptacles are available having built-in GFCI
protection and may be used for this measure of safety.
ELECTRICAL
EXTENSION CORDS
When using a power product at a considerable distance from
a power source, be sure to use an extension cord that has
the capacity to handle the current the product will draw. An
undersized cord will cause a drop in line voltage, resulting in
overheating and loss of power. Use the chart to determine
the minimum wire size required in an extension cord. Only
round jacketed cords listed by Underwriter's Laboratories
(UL) should be used.
When working outdoors with a product, use an extension
cord that is designed for outside use. This type of cord is
designated with "W-A" or "W" on the cord's jacket.
Before using any extension cord, inspect it for loose or
exposed wires and cut or worn insulation.
**Ampere rating (on product data plate)
Cord Length
25´
50´
100´
**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with a
power tool. Failure to do so can result in serious personal
injury.
Check extension cords before each use. If damaged
replace immediately. Never use product with a damaged
cord since touching the damaged area could cause
electrical shock resulting in serious injury.
5 — English
0-2.0
2.1-3.4
3.5-5.0
Wire Size (A.W.G.)
16
16
16
16
16
16
16
16
14
WARNING:
WARNING:
5.1-7.0
7.1-12.0 12.1-16.0
16
14
14
14
14
12
12
10
—