Pellet boiler stove first start-up time adjustment
This parameter indicates the time at which the pellet boiler
stove will be started: use buttons
desired time, with 10-minute steps.
Press button
to go to the following parameter.
UT06
Pellet boiler stove shutdown time adjustment
This parameter indicates the time at which the pellet boiler
stove will be turned off: use buttons
desired time, with 10-minute steps.
Press button
to go to the following parameter.
UT07
Week day selection
Press button
to select the days of the week. Press
button
to enable (ON) or disable (OFF) the pellet boiler
stove start-up day as shown in the following table:
Upper
MEANING
display
Day 1
Monday
Day 2
Tuesday
Day 3
Wednesday
Day 4
Thursday
Day 5
Friday
Day 6
Saturday
Day 7
Sunday
In the following example, the pellet boiler stove is only star-
ted on Saturdays and Sundays.
Day 1
Day 2
Day 3
Monday
Tuesday
Wednes.
off 1
off 2
off 3
Confirm and continue with key
UT08
UT16
continue as indicated above to set the second, third and
fourth ignition times.
and
to set the
and
to set the
Lower
display
ON1/OFF1-Yes or No
ON2/OFF2-Yes or No
ON3/OFF3-Yes or No
ON4/OFF4-Yes or No
ON5/OFF5-Yes or No
ON6/OFF6-Yes or No
ON7/OFF7-Yes or No
Day 2
Day 2
Day 2
Friday
Thurs.
Saturday
off 4
off 5
on 6
.
If the stove is controlled by an external thermostat, when
the thermostat reaches the preset temperature, "ECO TERM"
will be shown on the pellet boiler stove display.
the room temperature thermostat does not turn off and on
the pellet boiler stove; it sets the stove in saving mode.
Domestic hot water kit (optional)
Thanks to an optional kit, pellet boiler stoves can also pro-
duce continuous domestic hot water healthy, safely and au-
tomatically, without the need for water storing.
Domestic water pressure should not exceed 2 bars.
There is anyway an electronic control limiting the sy-
stem pressure to a max. value of 2,3 bar.
It is advisable to limit domestic water flow rate to approx.
8÷12 litres per minute in order to obtain a ∆T of approxima-
tely 25ºC.