REMARKS:
In case of repeated ignition lock-outs, while pellets are fed
regularly, there may be a problem caused by a failing elec-
tric glow plug. In this case, while you wait for a technician,
the pellet boiler stove can be manually started by using so-
lid fuel cubes (firelighters).
Manual starting procedure:
• open the door;
• take a solid fuel cube and place it inside the brazier toge-
ther with some pellets;
• light a match and set fire to the solid fuel inside the
brazier;
• wait a couple of minutes, close the door;
• follow the regular ignition procedure.
Do not use any flammable liquid to start the stove.
During the reload phase, do not bring the bag of pellets
in contact with the hot pellet boiler stove.
Working power and water temperature settings
The heating power is set by the
and
. A heating po-
keys
wer at Po 9 is suggested during
the first working hours of the stove.
To set the water temperature
press the key
only once. You
will see the words "Set H2o" blin-
king on the upper display. You
will read the water temperature
on the lower display.
Use the keys
and
wished value.
Water temperature range: 30°C – 80 °C
Room temperature setting
To set the room temperature,
press the key
twice: you
will see the words "SET ARIA" blin-
king on the lower display. You will
read the set temperature on the
upper display.
Use the keys
and
change the value.
Room temperature range: 7°C – 40 °C
Fan speed setting for hot air
It is possible to activate or deactivate the room ventilator pla-
ced on the front part of the stove.
The fan can be set with 5 different working speeds.
CAUTION!
to increase and reduce the
to
To set the fan for hot air, please join the following procedu-
re: press the key
room temperature. On the upper display, next to the room
temperature, there is a value which can go from 0 to 5.
Pressing the key to increase power
5 available speeds. If you set the value "0", you will deac-
tivate the fan.
On the following example, the
fan for hot air is switched off.
The speed is set on "0".
On the following example, the
fan for hot air is working at its
highest speed 5.
This adjustment is only useful for turning on and off the
hot-air delivery system because the temperature coming
from the grates depends on the pellet boiler stove status.
Procedure to turn off the pellet boiler stove
Turn off the pellet boiler stove by
pressing button
, for a couple
of seconds until "OFF" is shown
on the upper display.
Pellet feeding will stop immediately but the pellet boiler stove
will continue working until the accumulated heat is fully consu-
med, turning itself off automatically after approx. 30 minutes.
REMARKS:
The pellet boiler stove is fitted with
an automatic device that allows clea-
ning the brazier after a given period of
time: when this time is detected, the
stove fire automatically reduces and
"PUL FIRE" is shown on the display. After
some minutes, the pellet boiler stove
will start working regularly.
Do not unplug the power plug to turn off the pellet boiler sto-
ve; wait until the automatic shutdown cycle finishes: the con-
tinuous operation of the fumes extraction fan is normal and
may indicate that the stove is still hot. In the event of low tem-
peratures, it might happen that the stove - although switched
off - starts the smokes fan and circulator for some minutes in
order to prevent ice formation on the pipes of the system. in
the event there is a power drop, the main board will exhaust
the smokes residuals as soon as the power supply is back on.
In order to do that, the main board will increase the speed and
show the words "Cool FIRE" on the display. As soon as the co-
oling phase has been completed, the stove will automatically
start up working as it was set before the power drop.
6
twice to enter the setting menu for
you can scroll the
CAUTION!
WARNING