Pellet Boiler stove start up
The brazier should be cleaned before each starting.
Control Panel (Pict. 2)
Buttons
and
are used to adjust temperature, for
displays and for the programming functions.
Buttons
and
Button
is used to adjust temperature and programming
functions.
The upper and lower displays are used to view different
messages.
Pict. 2
1
6
LED
SYMBOL
DESCRIPTION
The LED is on when the parameter
UT01 on the menu is not on OFF and
1
the weekly or daily programming are
set.
The LED starts up every time the stove
2
is loading pellets
The LED blinks when the board signa-
lises a change in temperature or power
3
set by the infrared remote control.
The LED is on when the room tempera-
4
ture reaches the value set on the menu
SET Water.
The LED blinks to indicate that you are
entering the menu user/technician or
5
"SET"
that you are modifying the temperature
set.
The LED switches on when the water
6
circulator is working.
It is advisable to use dry wood pellets, up to 6 mm in
diameter.
CAUTION!
are used to adjust heating power.
2
3
4
5
CAUTION!

Preliminary checks

Before switching on the pellet stove, make sure that the pel-
let hopper is full, the combustion chamber is clean, the glass
door is closed, the power supply plug is connected and the
switch on the back is set to "1."
How to load pellets in the tank
You can load pellets in the tank through the door on the up-
per part of the stove.
Join the following procedure to load pellets:
• Open the door on the upper part of the stove;
• Load the wished pellets quantity with caution (load enough
pellets to grant a sufficient functioning of the stove);
• Close the door.
Starting the Stove
Press button
for a couple of seconds until the pellet boiler
stove starts.
"Fan" will be displayed on the up-
per display and "ACC" on the lower
one. During this phase the unit
will carry out a diagnosis (around
20 seconds) on the fume extrac-
tion system.
"LOAD WOOD" is the next phase,
which indicates pellets should
be fed. The glow plug will heat
up to light the fire.
When the fume temperature is
50º C (approx. 10 minutes), the
pellet boiler stove will confirm
the ignition: "FirE" will be shown
on the upper display and "ON" on
the lower one.
After this phase, which lasts
around 5 minutes, the heating
power (e.g. po 6) and the room
temperature (e.g. 25°), will be si-
multaneously shown on the upper
display, and the system delivery
water temperature will be shown
on the lower display.
If the flame does not start up correctly within 10 minutes, the
pellet boiler stove jams: you will read the words "ALAR" on the
upper display and the words "NO ACC" blinking on the lower di-
splay. Wait 10 minutes until the cooling phase is completed,
open the door, empty the brazier and start a new light-up.