Zibro DONATA 194 IDRO Mode D'emploi page 5

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
heating timer-thermostat
The heating timer-thermostat function is used to program
the pellet boiler stove to automatically turn on and off within
a period of one week.
To access programming, hold down button
three seconds, "UT01" will be shown on the upper display:
by pressing button
table below, the stove can be programmed according to
your needs. Press button
at any time.
These are the heating timer-thermostat parameters:
Parameter
Description
H. timer-thermostat ena-
UT01
bling and disabling. Day of
the week setting
UT02
Current hour setting
UT03
Current minutes setting
Technical parameters setting
UT04
Pellet boiler stove first start-
UT05
up time adjustment
Pellet boiler stove first shut-
UT06
down time adjustment
Week day selection, first
UT07
time activation
Pellet boiler stove second
UT08
start-up time adjustment
Pellet boiler stove second
UT09
shutdown time adjustment
Week day selection, second
UT10
time activation
Pellet boiler stove third
UT11
start-up time adjustment
Pellet boiler stove third shu-
UT12
tdown time adjustment
Week day selection, third
UT13
time activation
Pellet boiler stove fourth
UT14
start-up time adjustment
Pellet boiler stove fourth
UT15
shutdown time adjustment
Week day selelction, fourth
UT16
time activation
for around
several times and referring to the
to exit the programming phase
Programmable
values
OFF; Day 1, ...,Day7
From 00 to 23
From 00 to 60
Reserved
From 00:00 to 23:50 with
10-minute steps
From 00:00 to 23:50 with
10-minute steps
Between on/off for days
from 1 to 7
From 00:00 to 23:50 with
10-minute steps
From 00:00 to 23:50 with
10-minute steps
Between on/off for days
from 1 to 7
From 00:00 to 23:50 with
10-minute step
From 00:00 to 23:50 with
10-minute step
Between on/off for days
from 1 to 7
From 00:00 to 23:50 with
10-minute steps
From 00:00 to 23:50 with
10-minute steps
Between on/off for days
from 1 to 7
The meaning of the user parameters are explained in detail
below:
UT01
Heating timer-thermostat enabling and disabling and
current hour setting.
This parameter is used to set the current day of the week or
to deactivate the set programming.
Press buttons
and
shown in the following table:
Upper
Display
Day 1
Day 2
Day 3
Day 4
Day 5
Day 6
Day 7
Heating timer-thermostat disabled
OFF
Example:
if today is Thursday, select "Day 4"; but select "OFF" to
start the pellet boiler stove manually (without programming)
so that the heating timer-thermostat is disabled.
Press button
to go to the following parameter.
UT02
Current hour setting
This parameter is used to set the current hour, press
buttons
and
Press button
to go to the following parameter.
UT03
Current minutes setting
Press buttons
and
Press buttons
to go to the following parameter.
UT04
Technical parameters setting
Press button
to go to the following parameter.
7
to select the desired value as
MEANING
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
to select the current hour.
to adjust current minutes.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Donata 124 idroDonata 161 idro

Table des Matières