Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools Needed
Level
■
Drill with 1¼" (3.0 cm), 3/8" (9.5 mm), and 5/16" (7.9 mm)
■
drill bits
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Vent clamps
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Metal snips
■
Phillips screwdriver
■
Parts needed
Home power supply cable
■
1/2" (1.3 cm) UL listed or CSA approved strain relief
■
3 UL listed wire connectors
■
For vented installations, you will also need:
1 wall or roof cap
■
Metal vent system
■
For non-vented (recirculating) installations, you will also
need:
Recirculation Kit - See "Assistance or Service" section to
■
order.
6" (15.2 cm) dia. round metal vent duct - length required is
■
determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with blower, light bulbs, and canopy
■
glass already installed
Vent transition with back draft dampers installed
■
Metal grease filter
■
Vent cover support bracket
■
Mounting template
■
2-piece vent cover
■
Air deflector (for non-vented [recirculating] installations only)
■
2 - 3.5 x 9.5 mm T10 screws
■
4 - 4.2 x 8 mm T20
screws
®
■
6 - 5 x 45 mm mounting screws (for 8 x 40 mm wall anchors)
■
2 - 8 x 40 mm wall anchors
■
4 - 10 x 60 mm wall anchors
■
4 - 5.4 x 75 mm screws (for 10 x 60 mm wall anchors)
■
T10 Torx
adapter
®†
■
T20
Torx
adapter.
®†
®
■
†
TORX and T20 are trademarks of Acument Intellectual Properties, LLC.
®
4
INSTALLATION REQUIREMENTS
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall of the
vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see "For non-
vented (recirculating) installation only" in the "Connect Vent
System" section. Recirculation Kit Part Number W10294733 is
available from your dealer or an authorized parts distributor. All
openings in ceiling and wall where canopy hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280) or when
such standard is not applicable, the standard for Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with
local codes.
Product Dimensions
10⁷⁄₈"
4⁷⁄₈"
(27.6 cm)
(12.3 cm)
13³⁄₁₆"
(33.5 cm)
30" (76.2 cm) or
36" (91.4 cm)
*For non-vented (recirculating) installations
**For vented installations
5¹⁵⁄₁₆"
(15.0 cm)
*27⁵⁄₁₆" (69.4 cm) min.
45¹⁵⁄₁₆" (116.6 cm) max.
21"
(53.3 cm)
14³⁄₄"
**27⁵⁄₁₆" (69.4 cm) min.
(37.6 cm)
42" (106.7 cm) max.
1¹³⁄₁₆"
(4.6 cm)
19¹¹⁄₁₆" (50.0 cm)