English
11.3.1.4 RS485
Baud Rate
You can set the transmission speed using the baud rate. The default setting is
9600 bps. You can select between 2400 bps, 4800 bps, 9600 bps, 19200 bps and 38400 bps.
Data Bit
Setting for the data size for transmissions. You can select between 5, 6, 7 and 8 bits.
Stop Bit
Setting for the stop bit value for the data transmission. You can select either 1 or 2.
Parity
Set the parity to check the error-free transmission of data packages.
You can select from the following settings: "None", "Even" and "Odd".
Flow Ctrl.
The flow control is required to transfer information to the Speed Dome that the data transmission is
being performed too quickly and data packages are being lost.
You can select between: "None", "Hardware" and "Software".
PTZ Protocol
Selection of the protocol for controlling the Speed Dome.
You can select between "ABUS", "PELCO D" and "PELCO P".
PTZ Address
Assignment of the Device ID. You can select an ID from between 0 and 255.
Apply the settings made with "Save".
91