2610051575.qxp_GDE18V-16D 8/29/18 2:30 PM Page 14
Fig. 9
13
C.
At the end of every day, or If upon
inspection there is still dust on the
HEPA filter 13, follow the steps
below:
1. Remove the HEPA filter from the
dust box 12 by pressing both locking
tabs 14 inwards and pulling the HEPA
filter 13 out of the dust box (Fig. 9).
2. Use vacuum cleaner equipped with
HEPA filter, to remove accumulated
dust from the HEPA filter being
cleaned. Using a vacuum cleaner
regularly to clean the HEPA filter will
extend filter life.
3. If vacuuming the HEPA filter 13
▶ Service
unauthorized personnel may result in
misplacing of internal wires and
components which could cause serious
hazard. We recommend that all tool
service be performed by a Bosch
Factory Service Center or Autho rized
Bosch Service Station.
▶ Cleaning
the tool from the power supply before
cleaning or performing any main -
tenance. The tool may be cleaned most
effectively with compressed dry air.
Always wear safety gog gles when
cleaning tools with compressed air.
14
Operating instructions
12
14
Maintenance
Preventive mainte -
nance performed by
To avoid accidents
always dis connect
does not remove the accumulated
dust, replace the HEPA filter as this
indicates the life of the HEPA filter
has expired.
liquids and do not use compressed air
to blow it clean. There is a risk of
damage to the filter.
▼ REPLACING THE HEPA FILTER:
1.
Place the new or cleaned HEPA filter
13 back in the dust box 12. Press the
filter until it is fully secured by the
locking tabs 14. (Fig. 9)
2.
Slide the dust box 12 into the dust
extraction attachment. The dust box
is secured when the locking tabs 5
snap into the locking position
(Fig. 8).
NOTE: You may have to apply extra
force on the bottom of the dust box for
proper seating into the dust extraction
attachment.
To
placement, pull on the black tabs,
without pressing, to confirm that the
dust box is locked in place.
Ventilation openings and switch levers
must be kept clean and free of foreign
matter. Do not at tempt to clean by
inserting pointed objects through
openings.
damage plastic parts. Some of these
are: gasoline, carbon tetrachlo ride, chlo -
rinated cleaning solvents, ammonia and
house hold detergents that contain
ammonia.
Do not clean the
HEPA
filter
with
confirm
proper
Certain
cleaning
agents and sol vents