ENGLISH
OPERATING INSTRUCTIONS
Once connected to the mains the device starts running.
Regular breaks during operation are essential to maximize the life of this device as it is not designed for
continual use.
Do not switch the unit on and off in short time intervals as this reduces the lamp life.
The units' surface temperature may reach up to 85°C. Don't touch the housing with bare-hands during its
operation.
Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.
In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
Important: Never look directly into the light source! Don't use the effect in the presence of persons
suffering from epilepsy.
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
AC 100V-240V 50/60Hz
Power consumption:
26W
Fuse:
250V T6.3A slow blow (20mm glass)
Sound Control:
Internal microphone
DMX connections:
3pin XLR male / female
DMX channels used:
1 or 5 channels
Lamp:
8x 3W (2x red, 2x green, 2x blue, 2x White)
Size:
510 x 120 x 150.8 mm
Weight:
4.3kg
JB SYSTEMS
®
OPERATION MANUAL
9/53
LED JIVE
ENGLISH
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS
10/53
®
OPERATION MANUAL
LED JIVE