Prior to Mounting

The unit has been designed for mounting on level, solid
walls or ceilings.
Please observe the prescribed mounting position
(condensate drain at the bottom; see Fig.2, Item 11)!
When selecting the desired mounting location please
observe the following
– the remarks under «Important Instructions»,
– the coverage zone depends on the mounting height
and directions of approach (ascending stairs, sloping
terrain etc.),
– the watchdog must not be concealed by objects
(projecting roofs, twigs etc.),
– the minimum (vertical and horizontal) distance to light
sources must be 1.5 m,
– the watchdog must not affected by heat sources,
– the integrated dusk sensor must not be exposed to
direct light (from lamps or sun radiation).
– Do not position the sensor head such that it directly
faces light or heat sources or reflecting surfaces (eg
window panes, water surfaces).