Elektrischer Anschluss
Connections Provided by the Customer at Connection Board AB076
Actuator with AC Synchronous Motor
Terminal 8:
Terminal 9:
Terminal 10:
Ter. 11, 12, 13: OPEN
Ter. 11, 12, 13: CLOSE
Electrical connection
Holds the neutral conductor to provide for current flow, if necessary.
L - 230V AC line voltage for supply
Holds the protective conductor witch is used -as indicated by the name-
for protective function only. All conductive parts are thereby connected
to ground.
Elect. Controlling via current signal 4...20mA
Terminal 11: Feedback "actual value"
Terminal 12: Setpoint (current value increases
Terminal 13: GND
Effects this a rotation to position OPEN : at clockwise - actuators
standard. Looking onto the shaft from 12.00 o'clock to 03.00
o'clock.
At anticlockwise actuators the rotation affects to the other side.
Looking onto the shaft from 12.00 o'clock to 09.00 o'clock.
Do not use terminal 11 as position feedback at ETAMATIC / VMS /
FMS !
Use signal of potentiometer, terminal X20 / 21 / 22 !
Elect. Controlling via current signal 4...20mA
Terminal 11: Feedback "actual value"
Terminal 12: Setpoint (current value decreases
Terminal 13: GND
Effects this a rotation to 12.00 o'clock, position CLOSE :
at clockwise - actuators standard.
Looking onto the shaft from 03.00 o'clock to 12.00 o'clock.
At anticlockwise actuators the rotation affects to the other side.
Looking onto the shaft from 09.00 o'clock to 12.00 o'clock.
Do not use terminal 11 as position feedback at ETAMATIC / VMS /
FMS !
Use signal of potentiometer, terminal X20 / 21 / 22 !