Battery Care And Maintenance - Wayne WSM3300 Instructions De Démarrage Rapide

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions and Parts Manual
the System tallies and remembers the number of rings.
2. On your second call within "3" minutes, let the phone ring
until the System answers. The System will answer
first because it remembered the first "3" rings, and then
answers with an audible system status. If done properly, the
answering machine/voice mail will not answer.
If the System is set to answer in 10 rings (one of
the Menu selectable options), you will need to
place more calls within "3" minutes to get the System to eventually answer.
HOW TO CANCEL ALARM PHONE CALLS FROM YOUR
SYSTEM
To cancel the alarm phone call from one of the numbers in the
phone call list:
To cancel a call out sequence from the System while listening to
an alarm message, do the following:
1. Answer the phone call.
2. Listen to the alarm message.
3. When told, press the number "1" key followed by the
pound (#) key within "1" minute to cancel the alarm call
out. You can cancel the call at anytime during the
message.
4. You can listen until you hear the System say goodbye
or just hang up the phone.
5. If you do not cancel the call, the system will call the next
number in your phone number list. The first cancel will
stop all calls for all numbers. This sequence will repeat
every 15 minutes until a call is cancelled.
To cancel the alarm phone call using the System display:
Press and hold the RESET button once to cancel the call (phone
icon is present) and the RESET up to 5 seconds if multiple
errors/alarms are present on the display to stop receiving phone
calls. You will then be required to also clear/reset the message(s)
on the display.
Canceling the call out sequence does not
cancel an active alarm. System will continue
to beep and the alarm message will be displayed on the digital display
until you hit reset for each message/condition. If you do not hit reset, each
alarm message on the display system will recall the phone number(s) in
the last 72 hours as a reminder for the uncleared alarm conditions.
PLACE A PHONE CALL TO YOUR SYSTEM TO CANCEL AN
ALARM
To cancel a call out sequence during an active alarm condition,
do the following:
1. Make the call to the System (phone number at alarm
location)
2. Wait for the System to answer (5 or 10 rings Menu option
selectable)
3. Listen to the alarm message.
4. Press the number "1" key followed by the pound (#) key
anytime during the message to cancel the alarm call out
and then hang up the phone.
REMOTE STATUS CHECK
The System will answer incoming calls if a warning condition
exists on the display. When no alarm issue exists, you will get
a general status update. If the call out sequence has been
cancelled for an alarm by pressing "1" then "#" on the phone,
but the alarm condition still exists on the display, the System will
answer and describe the alarm condition.
CANCELING AN ALARM CALL OUT SEQUENCE WITH AN
ANSWERING MACHINE/VOICE MAIL DEVICE ON THE SAME
PHONE LINE
To cancel the alarm call out-sequence, do the following:
STEP ACTION
1. Make the call to the System (phone number at alarm
location).
2. Let the phone ring the desired number of times (before the
other in-line answering machine/voice mail can answer), Hang
the phone up.
3. Call the number a second time within three minutes (The
System keeps track of all the rings from the previous
calls, accumulates them until the total ring count matches its
ring count number, 5 or 10, and then it will answer). Listen to
the alarm message.
4. Press the number "1" key followed by the pound (#) key
anytime during the message to cancel the alarm call out. Hang
up the phone.
OPERATION
1. After installation, the back-up pump will start once the water
level raises the bottom float.
2. The System has a charging circuitry designed to optimize the
recharging time of your battery and to prevent overcharging.
In addition, the control box has a time delay which keeps the
pump from repeated, short cycles when it shuts off. This
time delay feature will allow the pump to run 15 seconds
after the switch reaches the off position.
3. MUTE FUNCTION: Press the mute button once to silence the
alarm for 12, 24, or 48 hours (menu selectable). To turn off the
mute timer, press and hold the RESET button down for 5
seconds.

BATTERY CARE AND MAINTENANCE

Explosion hazard. Smoking
and open flames prohibited.
Battery recharging and connections MUST be performed
in a well ventilated area. Before servicing the batteries,
blow away the gases by waving a piece of cardboard near
the batteries.
1. Unplug the transformer.
2. For batteries with top caps that can be removed, the
electrolyte level should be checked and filled to
manufacturer's specifications. The charge for each cell
should be checked with a hydrometer. A specific gravity of
1.265 indicates the battery is at full charge. If the specific
gravity of any of the cells varies more than .050, the battery
should be replaced.
3. If the battery fluid levels are low or battery plates are exposed,
refer to the manufacturer's recommendations on how to
replenish properly.
4. Inspect the terminals and clamps for corrosion and
tightness. Clean and tighten as required.
An inexpensive hydrometer can be purchased at
an automotive parts dealer.
EXTENSION CORDS
We DO NOT recommend using extension cords, but if you find it
absolutely necessary then:
1. Use at least a 16 gauge cord that does not exceed 50 feet
in length.
7
WSM3300
www.waynepumps.com

Publicité

Table des Matières
loading

Table des Matières