Les langues disponibles

Alarm Input
Connect this terminal to sensor devices, such as
an infrared sensor, door sensor, metal sensor,
manual switch, etc.
Input requirements
● No-voltage relay NPN open collector input
● Polarity of input detection can be selected
using a software
● Make/Break (500 ms and above)
● Circuit current at low level: 0.3 mA
● Applied voltage at high level: 3.3 V
Camera unit
DC3.3 V
R
Input 1
or Input 2
3.3 V
GND
(Alarm input equivalent circuit)
Alarm Output
Connect this terminal to annunciating devices,
such as annunciators, indicators, lights, buzzers,
etc.
Output requirements
● Equivalent to NPN open collector output (Set
the output put logic via the Internet Explorer)
● Allowable applied voltage: DC12 V and below
● Allowable inflow current: 50 mA
● Momentary (100 ms - 5000 ms) output
(Set time via the Internet Explorer )
Camera unit
Output 1
or Output 2
GND
(Alarm output equivalent circuit)
Note :
● Connect the GND cable of this camera to the
GND of the annunciating device.
Sensor
example (1)
VCC
R
OUT
0.3 mA
GND
Sensor
example (2)
Relay switch etc.
OUT
GND
annunciating
devices
DC 12 V
R
IN
GND
Image adjustment
When the camera is mounted, adjust the image
settings while looking at the actual image.
Mounting the test monitor
Connect the [MONITOR] terminal of the camera
to the test monitor to adjust the camera shooting
direction, field angle and focus.
T When configuring, turn on the power of the
camera.
Test monitor
[MONITOR]
terminal
75 K terminated
E-27