A. Laying in screed (30-50 mm)
1 Tile fl oor covering (tiles or natural stone)
2 Adhesive
3 Watertight layer (optional for wet areas)
4 Special screed for underfl oor heating systems (30 – 50 mm)
5 T2Blue heating cable
6 Metal/mesh
7 Plastic foil
8 High density polystyrene insulation (thickness 30 – 50 mm)
9 Subfl oor construction (concrete, tiles, wood, PVC, ...) without thermal
insulation
B. Laying in self leveling compound (15-30 mm)
1 Tile fl oor covering (tiles or natural stone)
2 Tile adhesive
3 Watertight layer (optional for wet areas)
4 Special (self-levelling) mortar for underfl oor heating systems
(≥ 15 mm)
5 T2Blue 10 W/m
6 Metal/mesh (optional only needed for wooden
combustable subfl oors)
7 Existing fl oor (tiles, wood, PVC, ...) with thermal insulation
Heating cable adhesive
(not included in all packs, can be ordered separately)
Properties
The heating cable adhesive is a rod-shaped hot melt adhesive for hot
adhesive guns (∅ 12 mm), which is extremely adhesive. The adhesive has a
processing time of 30 seconds, depending on the size, temperature and ther-
mal conductivity of the material to be glued. The correct strength is achieved
when the adhesive or glued joint has cooled to room temperature.
Processing temperature: +200° to +220°C.
Temperature resistance: +70°C.
Storage: at room temperature.