ANY OF THE STEAM BATH PRODUCTS CAN BE PURCHASED AT
YOUR LOCAL DEALER. Available aromas:
Eucalypt
Lavander
Rosemary
DO NOT SWALOW, DO NOT KEEP IN REACH OF CHILDREN, ALWAYS
KEEP THE CONTAINER CLOSED. PRODUCT EVAPORATES EASILY.
CLEANING AND DISINFECTING THE BATH
As listed for each installation, pulverized disinfectant is also supplied. This
product is provided in a one liter container and iss a fungicide and an anti-
bacterial. It destroy germs which cause bad odors.
The purpose of this product is for the user to always enjoy the steam bath in
the same optimal conditions for use, preventing any possible bad odors, the
proliferation of fungus or bacteria, which will prevent contagion.
Cleaning product
An appropriate product to remove dirtiness on walls, ceilings, floors and
benches in the bath. It does not leave an door on the surface or area. It also
contains a disinfectant which exercises a powerful residual disinfecting
action.
Application:
It is applied by wiping the surface areas with a spone or duser soaked in the
product. Glover are recommended. In private baths, it is recommended to
disinfect once a week to once a month and in public baths, daily or once a
week. It depends on the level of use.
Disinfectant Product
Use after cleaning, once the area is cool. It is a broad-spectrum fungicide
and antibacterial product
Application:
It is applied by pulverizing towards the floor and benches inside the bath
Pine
Thyme
Lemon
. In public baths, this disinfection should be done daily before being heated,
even if it wasn't cleaned the day before. This product can also be applied at
the end of the day, once the bath has cooled.
Mint
DO NOT SWALLOW. KEEP OUT OF THE REACH OF CHILDREN. ALWAYS
KEEP THE CONTAINER CLOSED.
The inforamtion contained in this manual is, to our knowledge, correct.
Nevertheless, given that the conditions under which there products are used
out of our control, we can not be held liable for the consequences of their use.
Power of the necessary equipment relative to the size of
the bath
Equipment
Cubic meters
power
From 0 to 2.5
From 2 to 6
From 6 to 12
From 12 to 17
From 17 to 33
From 33 to 42
From 42 to 52
Sections and electrical line protection
Power
4 Kw
4 Kw
6 Kw
6 Kw
6 Kw
9 Kw
9 Kw
12 Kw
12 Kw
18 Kw
18 Kw
21 Kw
21 Kw
24 Kw
24 Kw
19
Number of generators
4Kw
1
6Kw
1
9 Kw
1
12Kw
1
18Kw
2
21Kw
2
24 Kw
2
Voltage
Section of cable
220-II
4 m/m
220-II
2.5 m/m
220-II
10 m/m
220-II
4 m/m
380-II
2.5 m/m
220-II
6 m/m
380-II
4 m/m
220-II
10 m/m
380-II
6 m/m
220-II
16 m/m
380-II
10 m/m
220-II
25 m/m
380-II
16 m/m
220-II
25 m/m
380-II
16 m/m
Number of pipes.
1
1
1
1
2
2
2
Circuit breaker
20A
15A
30A
15A
10A
25A
15A
35A
20A
30A
50A
60A
35A
65A
40A