Astralpool VAP-2 Manuel D'installation Et D'emploi page 42

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Panel level probe:
To control the level of water, the boiler has a probe with two levels at the
same high. If one of them stop working it is detected and start to work the
other one.
To access to this panel press during some seconds both key ot the timer.
This panel will show the state of the level probe, for example if we see NIV
1:ok-Niv 2 X, it means level 1 works correctly and level 2 has been ingnored.
The system is designed to work in both levels, in the case that both probe are
damaged we will have to change the probe. Once it is changed we have to
set it in the equipment, access to this panel and reset with the key "Light",
one we reseted the sreen will show Niv1:OK-Niv 2 OK".
Water level of the boiler:
The fill in and fill up of the boilets is automatically. When swith on the bath the
boiler is filled in. After some second it will start to heating the water. The
system take care of having the boiler full during the functioning of the bath.
Once the water is heated it is converted in steam, the valve of filling in detect
if more water is needed and fill it up automatically.
Automatically cleaning of the boiler:
Once the bath is switch off the boiler is full, after one hour and a half, it starts
automatilcally the cleaning. It consits in opening the valves of fill in and fill up
during some time, after that it close the fill up valve and it fills in the boiler,
once it is full it is fill up again and it is ready for the next use. For the properly
use of the boiler use a descalcifier water with no more that 3 degrees of
hardness. Never has to be interrupted the electrical and water supply, if that
happens the boiler won't realise the cleaning.
All the functions of switch on and switch off of the bath has to be done
through the control panel, never from general switch and thermics.
Troubleshooting:
The system detects the problems more frequents. This are reflexed in the
panel. When a breakdown is produced it is enough with solving the problem
and switching on again the bath.
----Sonda Temp..corto.Avisen serv.tec.
The temperature probe has a short circuit.
----Sonda Temp.defet.Avisen serv.tec.
The temperature probe give a value above the desired temperature so it
means it is breakdown.
----Desagüe obturado.Avisen serv.tec.
The system it is trying to fill up the boile. The drain it is colapsed, or the valve
of fill up or level probe it is damaged.
----Detectada avería.Avisen serv.tec.
Contact with the after sales service.
----Alarma temp.Avisen serv.tec.
For an excess of temperature the security thermostat has set off. It has to be
normalised after switching on again.
----Cald. no se llena.Avisen serv.tec.
During many time the system is trying to switch on and there is any change in
the levels: there is no water supply, the fill in valve is damage, the fill up valve
is damage, the fill in valve it is open or the level probe is damage.
----No recibe datos.Avisen serv.tec.
The connection between the panel and the generator has some cable
brokken or disconnected.
----Ventil.apagada:Sistema parado
The ventilation is switch off manually with the bath working during more than
15 minutes and it appears this message on the panel. It is enough with switch
on again the ventilation.
----Vent.Invertido.Avisen serv.tec.
the fan of the precipitate of direct current it is connected on the other way
round, you have to invert the polarity.
----Agua no evapora.Avisen serv.tec.
The system has detected that after 20 minutes, there is no change in the
levels. Level probe damage, Bath temperature higher than the temperature
registered.
13

Publicité

Table des Matières
loading

Table des Matières