GAS CONNECTIONS
(continued)
EN
Figure 5
INFRARED BURNER FLAME ADJUSTMENT
Infrared burners do not require adjustment and need only be checked visually for proper
performance. On HIGH, an infrared burner should glow red evenly over its entire surface. A
diminished red glow and/or a large blue "halo" of flame on the surface of the infrared burner
indicates improper airflow or a blockage at the burner itself. Call for service.
SIDE BURNER FLAME ADJUSTMENT
Hestan side burners are preset at the factory for optimum performance. However, these valves
also feature a low flame (simmer) adjustment if altitude, low-heat performance, converting from
one gas to another, or other factors indicate an adjustment is needed. Follow the same procedure
as described above for Trellis Burner
™
valve adjustment.
NEVER ADJUST THE SIDE BURNER SO LOW THAT IT MAY GO OUT DURING
USE.