Dead man function setting
Ÿ Hold the P3 until the display shows
Ÿ Press repeatedly P2 until
Ÿ Press P3 to confirm and select with P2
Ÿ Press P3 to confirm the selection
Dip Switch meaning
Dip 1 ON : automatic reclosure enabled
Dip 1 OFF : automatic reclosure disabled
Dip 2 ON : inversion on start during closing enabled
Dip 2 OFF : inversion on start during closing disabled
Dip 3 ON : does not accept start when opening and opened
Dip 3 OFF : accept start when opening and opened
Dip 4 ON :
Dip 4 OFF :
Possible Errors reported on LED DS1
Error 1.
Short circuit.
Setup FF failure.
Capacitors charge failure.
High Temperature.
Instantaneous overcurrent.
Delayed overcurrent..
Bus overvoltage.
appears on the display
Button works like open command
Button works like start command
e release P3.
yes or
SW1
ON
ON
OFF
1
2
3
4
DS 1
88