General Characteristics :
Ÿ Programming and self-learning via keys (increase, decrease, validation) and a
figures display
Ÿ Management of three safety devices as photocell, a safety device inclosing and
in opening.
Ÿ Contact for signaling automation / alarm state
Ÿ 12Vac Contact for control safety / auxiliary functions power
Ÿ Serial with plug for external handheld ST-DISPLAY connection
Ÿ Inputs status Self-diagnosis and function parameter display by ST-DISPLAY
Ÿ Predisposition plug-in Radio
Ÿ Extractable power and signal Terminals
Ÿ Predisposed for coupling with filter FL_01
Ÿ Complies with European Directives Reference:
Low Voltage 73/23 / EEC
Electromagnetic Compatibility (EMC) Directive 89/336 / EEC
(NB: only if installed mains filter FL-01 or equivalent)
Specifications:
Power supply
Output Motor
Three phase motor connection
Single phase motor connection
Motor power
Environmental conditions
Accessories power supply
Protections:
Ÿ Motor protected by a fuse and electronic control
Ÿ Power circuits electronically protected by varistors.
Ÿ Secondary transformer, protected by self-resetting fuse and transil.
Ÿ Filter capacitors on the input network
ST DISPLAY
230Vac
Three phase230 VAC – Single phase 230 Vac
Triangle
No capacitor
2HP
-20°C / + 55 °C
12-24 VDC/AC – 4 Watt
For higher powers, install an external transformer
FL01