Features; Ups Features - Tripp-Lite SmartPro SMART1500LCD Manuel De L'utilisateur

Masquer les pouces Voir aussi pour SmartPro SMART1500LCD:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Features

UPS Features

MODE
MUTE
16-02-426-933072.indb 8
ON/OFF/MODE Button: Press and hold for 2 seconds to turn on the
UPS and 2.5 seconds to turn the UPS off. When the UPS is on, tap
this button repeatedly to advance through LCD screens. If utility power
is absent, pressing and holding this button for 2.5 seconds will
"cold-start" the UPS; i.e. turn it on and supply power to the outlets
from its batteries.
MUTE/ENTER Button: Use this button to toggle selection options for:
self-test, enable/disable alarm, LCD brightness, Sensitivity Control,
Scroll Control and the External Battery Setting Control. This button
can also be used to temporarily mute an active alarm by briefly
pressing it.
Tel/DSL Line Protection Jacks: These jacks protect equipment
against surges over a single phone line. Connecting your equipment
to these jacks is optional. Your UPS will work properly without this
connection. An RJ-11 cable is included with your UPS.
USB and RS-232 Communication Ports: These ports can connect
your UPS to any computer for automatic file saves and unattended
shutdown in the event of a power failure. Use with Tripp Lite's
PowerAlert Software (available as a FREE download at
www.tripplite.com) and appropriate USB or DB9 cable. Both a USB
and a DB9 cable are included with your UPS.
Notes:
1. This connection is optional. The UPS will work properly without this
connection.
2. This UPS System provides basic communication compatibility with most
integrated Windows
, Macintosh
®
applications.
Battery Backup Protected/Surge Protected Outlets: Provide both
battery backup and surge protection. Plug your computer, monitor and
other critical equipment into these outlets.
Note: Do not plug laser printers into the UPS.
Removable Mounting Hardware: Adapts the UPS to either tower or
rackmount (2U) applications.
External Battery Connector (XL model only): Use to connect a
Tripp Lite external battery pack for additional runtime. Refer to
instructions available with the battery pack for complete connection
information and safety warnings.
Note: Visit Tripp Lite on the Web at www.tripplite.com/support to locate the
specific battery for your UPS.
Resettable Input Circuit Breaker: Protects your electrical circuit
from overcurrent draw from the UPS load. If this breaker trips, remove
some of the load, then reset it by pressing it in.
, and Linux
power management
®
®
8
3/8/2016 3:27:59 PM

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Smartpro smart1500lcdxlAgsm8191

Table des Matières