1.3 - TECHNICAL SPECIFICATIONS
1.3.1 - RF Amplification
FORWARD WAY
Nominal gain without input bypass
Input attenuation
Interstage attenuation
Input equalization
Sloped response
Output level (42 channels, EN 50083-3; CTB: -60 dB, CSO: -64 dB)
Output level (129 channels, NCTA; CTB: -60 dB, CSO: -60 dB)
Noise figure
Output-1 test
Input test on internal F port
(1)
Subtract 11 dB if -2.7 dB by-pass (tap) is configurated. Ditto 4,5 dB if -4.5 dB by-pass (splitter) is configurated.
(2)
Add-up 10 dB if additional preamplification is implemented.
REVERSE WAY
Nominal gain
Input attenuation
Interstage attenuation
Input equalization
Output level (-60 dB, DIN 45004B)
Output level (-60 dB IMD2)
Noise figure
Output test on internal F port
1.3.2 - General
Remote powering voltage («TAL-880» models)
Mains voltage («TAL-890» models)
Consumption
Maximum AC/DC through current
Operating temperature
14
(1) (2)
configuration: 1 output
configuration: 2 symmetrical outputs
configuration: 2 asymmetrical outputs
if additional preamplification is not implemented
if additional preamplification is implemented
configuration: 1 output
configuration 2 symmetrical outputs
configuration: 2 asymmetical outputs
configuration: 1 output
configuration 2 symmetrical outputs
configuration: 2 asymmetical outputs
input bypass is not configurated
-2.7 dB input bypass is configurated
-4.5 dB input bypass is configurated
27 dB
(2x) 22.5 dB
26 and 16 dB
0, 3, 6, 9, 12 or 15 dB
0, 3 or 6 dB
0 to 8 dB
-6 to 18 dB
0, 6 or 12 dB
≥ 110 dBµV
≥ 105.5 / 105.5 dBµV
≥ 109 / 99 dBµV
≥ 44 dBmV
≥ 39.5 / 39.5 dBmV
≥ 43 / 33 dBmV
≤ 7 dB
-19 ±1 dB
-30 ±1 dB
26 dB
0 to 18 dB
0 or 6 dB
0 to16 dB
≥ 118 dBµV (≥ 58 dBmV) without input bypass
≥ 108 dBµV (≥ 48 dBmV) without input bypass
≤ 7 dB
-30 ±1 dB
-18 ±1 dB
-25.5 ±1 dB
24 to 90 V (AC or DC)
100 to 265 V
AC
21 W
7 A
-10° to +55° C