Adv Menu 22 – Factory Reset
Adv Menu 22 – Factory Reset on Menu Exit
Off
Input and Output
The programmable User keys on the TMC-1 are very powerful, this gives you a
selection of possible combinations
Off:
Input& Output
Input Select and Output Select + T/B to All
T/B+L/B:
Reset to factory and default user keys with T/B and L/B Keys
T/B only:
Reset to factory and default user keys with T/B Keys only
FO T/B or L/B:
Reset to factory and default user keys without T/B and L/B Keys
TMC-1-Penta: This command will not reset the input and output assignment
On all units:
Input and Speaker Names reset to defaults
User Keys Reset to defaults as selected in menu
All Gains set to 0dB-Unity
Cue routing as follows
SLS – Main
Cue1 – Cue1 input
Cue2 – Cue 2 input
Cue3 – Cue 3 input
Head Phones – Talkback
Automation
Play Start – Disable Talkback and Listen Back
Play Stop –
Record Start – Disable Talkback, Listen Back and Studio L/S
Record Stop –