USING THE OZONE DEVICE

Digital control

Applicable to Wood's Airmaster WOZ500/2000/4000
Normal operating mode
Pwr 100%
Use the forward (C2) and back (C4) buttons to set ozone production to the preferred level, 1-100%. The timer is switched off.
TimerOff
Menu
Menu
Press set (C3) to access the menu. Then use the forward button (C2) to scroll until you arrive at the function you want to change.
(You can always leave the menu by holding down the set button.)
Timer
Timer
Press set (C3), the set timer mode is displayed. Press set (C3), again, the text starts to flash. Use the forward button (C2) to scroll until you
Settings
find the preferred timer function. Press set (C3) to select a function.
Timer off (factory default)
Mode
Off
Shut-off timer
The Wood's Airmaster operates for the preferred time and then shuts off.
Mode
Press forward (C2), "Set Timer" appears in the display. Press set (C3), the text flashes, set the preferred time by pressing forward (C2) / back
Once
(C4) (e.g. 15 min 00:15). Press set (C3) to confirm the time (the timer stops flashing). Hold down set (C3) start the timer and leave the menu.
"TimedOut" is displayed when the timer has reached the end. Hold down forward (C2) and back (C4) at the same time to restart the timer.
Set the time in the following timer modes in the same way as described in Shut-off timer.
Interval timer
Mode
The Wood's Airmaster switches between operating mode and shutdown mode at set times.
Interval
First, set the operating time: "Step on". Press forward (C4). Then set the shut-down time: "Step off".
Daily timer
The Wood's Airmaster operates according to set times of day. NOTE: Set the clock first! (see Clock)
Set the "on" time 1: "Step on 1". Press forward (C2), set "off" time 1: "Step off 1".
Mode
Set "on" time 2: "Step on 2". Press forward (C2), set "off" time 2: "Step off 2".
Daytimer
Set "on" time 3: "Step on 3". Press forward (C2), set "off" time 3: "Step off 3".
If a mode (e.g. 3) is left blank, i.e. 00:00, that mode is disabled.
Clock
SetClock
This is where you set the clock used by the daily timer.
00:00
Press set (C3): the digits flash. Set the required time using forward (C2) and back (C4). Press set to confirm your setting. (24-hour backup in
the event of a power outage)
Backlight
The display backlight can be switched on or off.
B.light
On
Connection for external devices (USB)
The input for external devices (e.g. ozone meter) can be enabled or disabled. eller på.
ExtInput
Operating mode can be selected: Ozone Control – A connected ozone meter can control the ozone generator to maintain a constant
settings
ozone concentration. Ozone Alarm – If a connected ozone meter discovers a leak, the machine shuts down and alerts the operator.
Factory default
Restores the device to the factory defaults.
Factory
reset
Key lock
KEYS
The buttons are locked by holding down set (C3) and forward (C2) at the same time until "KEYS LOCKED" appears in the display. The
LOCKED
buttons are unlocked in the same way.
NOTE:
All settings will be deleted.