Operating Instructions
GB
USING AND MAINTAINING YOUR OZONE DEVICE
Use
Position the ozone device in a dry
place that is ventilated well, ideally
high up and approx. 1.5 m above the
floor. It is important to ensure that
nothing prevents the air entering the
fan.
Connect the mains cable supplied to
the mains socket (A4).
The ozone device can now be started
by pressing the on-off button (A3).
The ozone device starts in operating
mode, with full power (100%).
It can take up to about 5 minutes to
achieve the full effect.

Starting the machine

1. Start the ozone device.
Press the switch (A3) to ON
2. Switch off the ozone device
Press the power switch (A3) to OFF
Digital control with timer
(Applicable to Wood's Airmaster
WOZ500/2000/4000)
The ozone quantity/output can be
varied between 0 and 100%.
Timer modes: daily, interval and
shut-off timer.
See "Digital control" instructions on
the next page for further information.
Using the silicone hose
The nipple and silicone hose
accessory (E1) is mounted in the
connecting nut (B1) and the ozone
can be directed into the space to be
treated such as car interiors, partition
walls and water treatment.
Connecting to a ventilation duct
When connecting to a ventilation
duct/spiral pipe, the ventilation
12
nozzle (E5) is connected by means of
a nut rivet. The ozone device is then
connected with the hose nipple and
silicone hose (E1).
Maintenance
NOTE!
Always unplug the device before
carrying out servicing/maintenance.
Replacing the prefilter
The prefilter has to be replaced every
two to four months, depending on
the ambient environment.
1. Undo the filter holder (A2) by
hand.
2. Replace the filter with a new one.
3. Put back the filter holder (A2).
Replacing the ozone pipe
Ozone is formed when a high-voltage
power supply is passed into the
ozone pipe. The ozone pipe must be
replaced if the ozone concentration
declines or ceases entirely.
A. If your ozone device has four
chassis screws per long side:
1. Undo the eight screws on the long
sides of the chassis.
2. Lift the cover off the machine.
3. Go to point C.
B. If your ozone device has no
visible chassis screws:
1. Undo the two screws that hold the
handle in place.
2. Turn the machine upside down.
3. Undo the four screws that hold the
machine's feet in place.
4. Remove the chassis cover by
pulling/pushing the cover forwards.
5. Go to point C.
C. Replace the ozone pipe:
1. Carefully remove the two air hoses
from the ozone pipe (F4).
2. Undo the two cables between the
high-voltage module (F3) and the
ozone pipe (F4).
3. The screws that hold the ozone
pipe in position (F4) are undone
from the underside.
4. Assemble in reverse order.
NOTE:
The ozone pipe and prefilter
are wear parts and are not covered by
the warranty.
All servicing other than that
described here must be performed
by the manufacturer or an authorised
partner.
Servicing
You must contact your local dealer
if your ozone device requires
maintenance. Receipts must be
presented for all warranty claims.

Storage instructions

Store your ozone device at room
temperature between +1 °C and
+35 °C.
It is important to replace the
prefilter at regular intervals
and to replace the ozone pipe
regularly. Failing to do this may
impair the capacity of the ozone
device and possibly harm the
device.