USE, TESTING AND MAINTENANCE:
USE:
The gas detector is operational if the 9 volt battery is placed and the GA-10 is connected by adapter. You can only
place the detector on the ceiling plate if the 9 volt battery is installed. If the detector is operational the red LED will
blink. After calibration it will turn green.
Once gas is detected, the alarm will go off. A loud beep will sound and the red LED will blink continuously. Once the
gas dissipates, the alarm will stop automatically.
Testing:
By pressing the test key on the GA-10, the alarm can be tested to ensure it is still operational. Hold the key for
at least 2 seconds. Operation is correct if the red LED blinks and a tone is audible. Preferably check the detector
weekly. During alarm state, the GA-10 will generate a tone of at least 85dB(A) sound pressure.
Hush function:
With this function, the alarm will be deactivated for 5 minutes. This function can be activated by pressing the button
once, shortly. The red LED will blink to indicate the alarm is silenced. After 5 minutes, the blinking will stop and the
alarm will be reactivated
ATTENTION:
•
If there is any doubt over the cause of an alarm, then assume the alarm is caused by a gas leak and
evacuate the premises as soon as possible.
•
Keep the gas detector away from small children.
•
During renovations, protect the gas detector against dust. It will lose it's functionality if covered by dust.
Maintenance:
The GA-10 can be cleaned with a vacuum cleaner.
ENVIRONMENT:
Do not throw away used batteries, but recycle them using your local chemical depot. Product may not be thrown out
as normal waste, but must be recycled as electrical waste.
SPECIFICATIONS:
Usage temperature ................................................................... 4˚C tot 60˚C
Power ....................................................................................... 12VDC, 200mA + 9V DC backup
Alarm point ............................................................................... < 15% LEL
Sound level during alarm .......................................................... 85dB at 1 meter
PROBLEM
No sound during the test procedure
Note: Hold the test button several
seconds during a test.
The gas detector beeps every minute
The gas alarm regularly gives a false
alarm during cooking or during use of
the shower.
Green LED blinks every 30 sec.
Red LED blinks
SOLUTION
1. Remove the detector from the ceiling plate and check if the battery
and adapter is properly connected.
2. Clean the gas detector.
Replace the 9V battery and check the adapter.
1. Clean the gas detector.
2. Move the gas detector to another location.
Device not connected on main power, but works on battery.
The device is still warming up or hush mode is active.