LRF-04
User''s manual
-
Maximum permitted equivalent emission level for the night time zone.
-
Maximum permitted equivalent reception level for the night time zone.
-
Equivalent session level.
Duration of 60 dB penalisation, when this occurs (Attenuation time).
-
Emission exceeded: time in seconds, during the interval, that the sound
-
pressure measured in emission has exceeded the maximum emission
level programmed, or, the LRF-04 has applied an attenuation of 60 dB, or
with the ENOS option activated, the LRF-04 has overridden the
attenuation.
Reception exceeded: the definition as for emission exceeded, but for the
-
maximum reception level programmed.
Time in seconds during which the LRF-04 has penalised with 60 dB
-
attenuation and the measured emission sound pressure level has
continued to exceed the programmed limit during the session (Emission
exceeded).
-
Time in seconds during which the LRF-04 has penalised with 60 dB
attenuation and the calculated reception sound pressure level has
continued to exceed the programmed limit during the session (Reception
exceeded).
-
Time in seconds during which the LRF-04 has been disconnected from the
mains (Disconnections).
Time in seconds during which the sensor has been tampered with during
-
the session (Sensor inac.).
Maximum "Fast" level measured during the session and the number of
-
seconds during which the "Fast" level has exceeded the programmed limit
for the session (emission).
Level, date and time of the maximum 1-minute Leq obtained during the
-
session (emission).
Level, date and time of the minimum 1-minute Leq obtained during the
-
session (emission).
The percentiles obtained during the session: L1, L5, L10, L50 and L90
-
(emission). An Lx percentile indicates the sound pressure level exceeded
during x% of the interval time.
13/09/99
14/09/99
22:30 < --> 03:00
Emi.day lim.:
90 dBA
Rec.day lim.:
40 dBA
Disconnection:
0 s
Sensor inac.: 0 s
LF max :
87.0 dBA
Exceed.: 1235 >85 dBA
BATTERY RUN OUT: Before the battery runs out, the LRF-04 records the day and time
-
when this occurred. You may consult the last 10 times this happened by selecting this
option from the display menu.
-
REPROGRAMMING: This option allows you to consult the last 10 dates on which the
LRF-04 was programmed.
-
DELETIONS: This option tells you the last 10 occasions on which the LRF-04 data was
deleted.
Night timetable:
22:00 <-->
Emi.nig.lim.:
85 dBA
Rec.nig.lim.:
35 dBA
MaxLeq1':
86.4 dBA
14/09/99
02:55
MinLeq1':
UND dBA
13/09/99
23:51
33
Leq :
08:00
Attenuat. time:
Emissi. exceed: 0
Recep. exceed: 0
Percentiles (dBA)
L1
: 86.3
L5
: 84.2
L10 : 81.5
83.2 dBA
2 s
L50: 81.1
L90: UND