DISH WASHER ELECTRONIC PCB. BASE VERSION.
The factory menu allows the factory or the installing tecnician to program all the various
Functions of the machine, according to the following table.
PARAMETER
P00
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
P11
P12
P13
P14
P15
P16
P17
P18
P19
P20
P21
P22
ENGLISH
DESCRIPTION
BREAK TANK OPTION : 0 = not installed , 1 = installed
Preset at 0
DRAIN PUMP OPTION: 0 = not installed, 1 = installed
Preset at 0
BOILER SAFETY FUNCTION : 0 = not enabled , 1 = enabled
Preset at 0
COLD RINSE FUNCTION : 0 = not installed, 1 = installed
Preset at 0
REGENERATION FUNCTION: 0 = not installed , 1 = installed
Preset at 0
BOILER TEMPERATURE SET POINT , from 60 to 95 °C
Preset at 85 °C
TANK TEMPERATURE SET POINT, from 40 to 65 °C
Preset at a 55 °C
SHORT WASH CYCLE TIMER , from 0 to 120 sec.
Preset at 60 sec.
MEDIUM WASH CYCLE TIMER , from 0 to 180 sec.
Preset at 120 sec.
LONG WASH CYCLE TIMER , from 0 to 240 sec.
Preset at 180 sec
CONTINUOUS WASH CYCLE TIME-OUT, from 0 to 30 min.
Preset at 10 min.
PAUSE TIMER , from 2 to 30 sec.
Preset at 4 sec.
RINSE TIMER , from 5 to 60 sec.
Preset at 17 sec.
DETERGENT TIMER ( 1ST CYCLE ), from 20 to 240 sec.
Preset at 120 sec.
DETERGENT TIMER ( NORMAL) , from 2 to 60 sec.
Preset at 20 sec.
SHINE TIMER , from 0 to 60 sec.
Preset at 10 sec.
DRAIN CYCLE TIMER , from 30 to 180 sec.
Preset at 120 sec.
COLD RINSE TIMER , from 0 to 60 sec.
Preset at 10 sec.
NUMBER OF CYCLES FOR AUTOMATIC DRAIN, from 0 to 250
Preset at 0 ( function disabled )
BOILER HEATING TIME-OUT, from 2 to 40 min.
Preset at 20 min.
TANK HEATING TIME-OUT, from 2 to 40 min.
Preset at 30 min.
WATER LOAD TIME-OUT, from 1 to 20 min.
Preset at 10 min.
DRAIN TIME OUT, from 1 to 10 min.
Preset at 4 min.