LUBRICATION
All models may operate without airline lubrication. However, operating the tool without airline lubrication may reduce tool performance and vane life.
If an airline lubricator is not used, it is recommended that the tool be oiled daily before use to improve performance. Add 2-4 drops of air motor oil and
run the tool for 10-20 seconds to distribute oil through the tool.
For maximum performance and tool life, an air line lubricator, set to deliver 2 drops per minute, is recommended. SIOUX No. 288 Air Motor Oil is rec-
ommended.
CHANGING WHEEL
1. Remove flange.
2. Remove old wheel.
3. Install the new wheel onto the arbor. Make sure the wheel is flush against the face of the arbor and the hole in the wheel fits over the boss on
the arbor.
4. Secure the wheel to the arbor with the screw and flange. Make sure the undercut on the flange faces the wheel. Make sure the wheel is securely
attached to the arbor.
MAINTENANCE
Water, dust and other airline contaminants can cause rust and vane sticking. For long periods between tool use, flush the tool with a few drops of oil
and run for 10 seconds. This will help remove contaminants and reduce the formation of rust.
OPERATION
The tool is intended to cut with the edge of the wheel. Apply the tool to the work with light pressure, allowing the wheel to cut. Keep the wheel square
with the cut. Do not apply side loads
The tool is equipped with a locking type lever in order to prevent accidental start-up.
Speed of the tool may be adjusted by turning the regulator, which is located opposite the lever.
Catalog
Noise* (Tested in accordance with ISO Standard 15744)
Number
*Sound Pressure (dBA)
SCO10S253F
89.0
SCO10S253R
87.8
SCO10S204F
90.3
SCO10S204R
91.6
SCO10S184F
89.1
SCO10S184R
87.8
SCO10A125
87.3
SCO10A106
91.2
Disconnect tool from air supply before installing or removing wheel or making any adjustments
NOISE AND VIBRATION READINGS
*Sound Power (dBA)
100.6
99.5
101.9
103.2
100.7
99.4
98.9
102.8
WARNING
Uncertaintity (dBA)
3.0
3.0
3.0
6.3
3.0
3.0
3.0
5.5
3
Vibration* (Tested in accordance with
ISO Standard 28927-1:2009)
*Vibration m/s^2
Uncertaintity m/s^2
3.78
6.00
9.63
11.50
6.27
5.42
4.27
6.62
0.60
0.13
2.27
3.70
0.06
0.06
1.08
1.34