INSTRUCTIONS & PARTS LIST FOR SSR6P25 SKIN CLAMP RUNNER
Read and understand these instructions before operating this tool.
Everyone using, maintaining, changing accessories or working near this tool must read, understand and follow these Safety Instructions!
Skin clamp runners can cause flying particles.
Proper eye protection must be worn at all times by tool user and bystanders. Failure of the workpiece accessories or the
inserted tool can cause high velocity projectiles. Ensure the workpiece is securely fixed. Wear impact resistant eyewear. Check
the free speed of the skin clamp runner regularly without the bit installed. Ensure the sparks and debris from use do not create
a hazard. Disconnect the skin clamp runner from the energy supply before changing accessories or bits. Asses the risk to
others before operating the skin clamp runner.
Flying particles can cause eye injury.
Power tools generate noise.
Ear protection must be worn when tool noise level exceeds 85 dBA. We also recommend that ear protection be worn when
the tool noise level is below 85 dBA. See the tool's information sheet for the noise level. High noise levels can cause hearing
damage. Keep tool maintained to prevent an increase in noise and vibration. Ensure that the muffler is still installed.
Prolonged exposure to noise can cause hearing loss.
Power tools vibrate.
Excessive vibration can cause injury. If numbness, tingling, pain or whitening of the skin occurs, stop using tool and consult a
physician. See the tool's information sheet for the vibration level. Vibration exposure can cause disabling damage. Wear warm
clothing when working in cold conditions. Keep your hands warm and dry. Stop using the skin clamp runner if you experience
numbness, tingling, pain or whitening of the skin and contact a physician. Maintain the skin clamp runner as recommended to
prevent an increase in vibration levels. Do not use worn or ill-fitting sockets or extensions as this is likely to increase vibration
levels. Support the tool in a stand, tensioner or balancer if possible. Do not hold the tool too tightly. Improper or damaged
inserted tools can cause excessive vibration.
Prolonged exposure to vibration can cause injury.
Skin clamp runners present a risk of entanglement.
Keep loose hair away from power tools and accessories. Keep hands away from moving parts of the tool and accessories. Do
not wear jewelry, loose clothing, or neckwear around power tools. Keep work area clear of cleaning rags and all items that could
become entangled with the tool.
Entanglements can cause injuries.
This tool is not insulated for contact with electric power sources.
Do not use near live electric circuits.
Electric shock can cause injury.
This tool is not intended for use in a flammable or explosive atmosphere.
Do not use this tool in a flammable or explosive atmosphere.
Explosions and fire can cause injury.
When using a skin clamp runner, sudden and unexpected tool movement can occur:
Be sure your body position allows you to have control of the tool at all times. Make sure your footing is secure.
Sudden and unexpected tool movement can cause injury.
Using excessive force on a tool makes it hard to control.
Do not force tool.
Hard to control tool can cause injury.
Taping or wiring the throttle valve in the "ON" position will prevent the tool from shutting off if the tool should jam or malfunction or if
anything unexpected happens.
Do not wire or tape down the "On-Off" valve of any power tool.
Tools that are prevented from shutting off can cause injury.
Poorly maintained and lubricated tools can fail unexpectedly.
Keep tool properly lubricated and in good repair at all times. Use only Sioux Air Motor Oil No. 288. See the tool's information
sheet to find out what other greases and oils to use. Do not drop the end of the hose on the floor where it will pick up dirt and
transport it into the tool. See information sheet for any additional maintenance requirements.
Unexpected tool failures can cause injury.
Air under pressure can cause injury.
Shut of air supply, drain hose and disconnect from router before servicing or changing bits. Never direct air at yourself or
anyone else. Whipping air hoses can cause severe injury. Always check for damaged or loose hoses or fittings. Use lock pins
and whipcheck safety cables when using universal twist couplings. Do not exceed the maximum pressure stated on tool. For
torque-control tools, the air pressure has a safety critical effect on performance. Requirements for length and diameter of hose
shall be specified. Do not carry the tool by the hose. Wipe all couplers clean before connecting. Failure to do so can result in
damage to the quick couplers and cause overheating.
Whipping hoses and air pressure can cause injury.
250 Snap-on Drive • PO Box 1596 • Murphy, NC 28906 • USA • Phone: 828-835-9765 •www.siouxtools.com
Form ZCE779A
SERIAL "B"
SAVE THESE INSTRUCTIONS!
WARNING
When used improperly power tools can create hazardous situations.
Improperly used power tools can cause injury or death.
SKIN CLAMP RUNNER SAFETY
Original
Instructions
1
Form ZCE779A
Date 2017March2/B
Page 1 of 26
March2/B
Date 2017