Drilling The Piping, Condensation Hose And Cable Feed-Through; Connection The Coolant Pipes; Connecting And Disconnecting The Coolant Pipes For The Sc37Xx Models; Connecting And Disconnecting The Coolant Pipes For The S37Xx Models - Qlima SC 37 Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
7.2

Drilling the piping, condensation hose and cable feed-through.

a.
Determine the positions of the holes according to the diagram detailed in Fig. 9. Drill one (1) hole (≥
85 mm for SC37xx / ≥ 65 mm for S37xx) slanting slightly downwards to outdoor side, this will prevent
water to come indoors (fig 10).
b.
Always use wall hole conduit when drilling metal grid, metal plate or the like.
8.
CONNECTING THE COOLANT PIPES
8.1

Connecting and disconnecting the coolant pipes for the SC37xx models.

G
TAKE CARE
Connecting the coolant pipes of an air conditioner must be carried out in accordance with the
applicable national regulations and laws. Connecting the coolant pipes may only be carried out
by an authorised fitter.
G
TAKE CARE
The piping package, coupled to the interior unit, is heavy. Never let the piping package hang
freely from the interior unit. Support the whole piping package during installation of the interior
unit. The weight of the piping package can cause the piping on the interior unit to bend and
even break. Damage to the piping on the interior unit due to unprofessional installation and is
not covered by the guarantee.
G
TAKE CARE
For your safety, always wear safety eye wear and work gloves when connecting the pipes. The
piping is coupled the interior unit at the factory. Read through the "quick installation guide" to
understand how the piping and power cable must be connected to the exterior unit.
4
54
54
Wall
Outdoor
Indoor
≥5°
Figure 10

Publicité

Table des Matières
loading

Table des Matières