New Install - Always Pressure Up Slowly (Follow start up on page 9)
Problem
Fluid not owing through unit
No Clicking
Sound
Fluid owing through unit
Injector in Operation or After Scheduled Maintenance
Problem
Main Piston Assembly #9 worn
Cover #1 or lower housing #40
worn or scored
No Clicking
On/Off Lever in off position
Sound
By-Pass Valve not closed
Dirty or plugged inlet lter
#17 Worn or not seated properly
Problem
Cracked or loose Suction Hose
Dosage piston #44 (5% - #52) worn
or installed incorrectly
O-ring support nut #88 installed
Clicking
incorrectly
Sound
O-ring seat #14 or dosage piston
No Suction Of
#44 (5% - #52) damaged
Solution
Suction tube #25 or suction tube
tting #11 cracked, leaking or
clogged suction tube lter
Check valve #13 leaking
Problem
Clicking
#44 (5% - #52) Dosage Piston worn Replace.
Sound,
#7 Inner Cylinder worn
Unit operates at high- ow and not
Under
at low ow
Injecting or
Main Piston Assembly #9 worn
No Clicking on
Cover #1 or lower housing #40
Low Flow
worn or scored
Problem
Check valve #13 leaking
Fluid
Re- lling
Washer seal on #13 is swollen or
Solution Tank
chemical attack
English: 14
Troubleshooting
Cause
Are the red plugs at the inlet and outlet openings removed?
Is the unit installed backward? The arrow on the unit must point in the
direction of the uid ow.
Has the new injector been stored for an extended period. If so, submerge the
injector in room temperature uid for 24 hours so that the working parts can
reabsorb uid and swell back to the proper size.
If still not clicking, do not open the upper body. Call Dosmatic Customer
Service.
Fluid rate is below or exceeds rated service ow of injector. (see Speci cations
page 6).
If below increase ow rate, if above, reduce ow rate.
Operating pressure exceeds maximum limit. Install a pressure reducer valve.
(see Speci cations page 6).
On/Off Lever in off position. Place the On/Off lever switch to the ON position.
By-Pass Valve not closed. Check and set valve to the OFF position.
Cause
Replace # 9 Main Piston Assembly. Clean uid lter.
Replace.
Place the On/Off lever switch to the ON position.
Set Valve to the closed position.
Ensure mesh size is correct for proper ltration. Clean lter.
Re-seat #17 or replace.
Cause
Check for proper t and /or replace.
Replace. Ensure during maintenance replacement that #44 dosage
piston was installed correctly ared-end up.
Install correctly.
Replace.
Replace and/or clean as necessary.
Clean & replace as necessary.
Cause
Replace.
Replace #17 O-ring.
Replace # 9 Main Piston Assembly. Clean uid lter.
Replace. Install or clean uid lter.
Cause
Check seat area on suction tube tting #11. Check valve and seal must
t loose in the suction tube tting. Clean seal and inside tting for debris.
Replace with new check valve assembly.
Solution
Solution
Solution
Solution
Solution