Routine Maintenance Instructions
Step 1.
Unscrew #7 OUTER CYLINDER
from body.
Step 4.
Replace #44 DOSAGE PISTON.
Step 7.
Replace # 17 O-ring and re-
install and tighten #88 O-ring
SUPPORT NUT.
Fixed
Step 2.
Unscrew #52 LOWER SHAFT
using Dosmatic 6-1 lower
wrench (supplied).
Step 5.
Replace #14 O-ring.
Step 8.
Re-install #52 LOWER SHAFT,
#14 O-ring and #44 DOSAGE
PISTON.
Step 3.
Remove #52 LOWER SHAFT,
#14 O-ring and #44 DOSAGE
PISTON.
Step 6.
Remove #88 O-ring SUPPORT
NUT using Dosmatic 6-1 lower
wrench.
Step 9.
Screw #7 OUTER CYLINDER
onto body.