Maintenance; Remote Injecting - Hydro Systems Twist II Clean Mode D'emploi

Filtres en ligne
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Fig. 5
Remote Injector
Kit shown on a
single injector.
RINSE INJECTOR AFTER EACH USE
Additive allowed to remain in injector can dry, foul or
damage the lower end at the next start-up. Place suction
tube into a 1 qt. (0.95 liters) or more container of fresh
 ltered water. Flow fresh water through the injector by
operating until container is empty. This procedure is not
needed for continuous operation.
CLEAN SOLUTION CONTAINER
Keep covered to prevent dirt,  ies, feathers and other
 ying debris from entering the container. Rinse container
thoroughly and often. Do not mix chemicals together that
might react and cause a precipitate. Use FILTERED  uid
when  lling container.
CLEAN SUCTION TUBE FILTER SCREEN
Inspect each time new solution is added. Clean  lter screen
(#27) and suction tube (#25) as necessary by rinsing in
fresh water. Replace if necessary. Keep  lter screen off
bottom of solution container to prevent dirt and precipitate
from clogging  lter.
CLEAN INLET FILTER
Clean or replace inlet  lter as required to increase the life of
the unit as well as reduce pressure loss.
BYPASS INJECTOR
When not in use place the injector in bypass mode by using
the three valve bypass (preferred) or turn the
on/off lever on the top of the injector to the off position.
STORAGE
For extended storage, rinse injector (see "Rinse Injector
After Each Use") and place underwater in a container. Apply
monthly, <0.1 oz. (29 ml) of chlorine bleach to avoid algae
growth. KEEP FROM FREEZING.
English: 10

Remote Injecting

Remote Injector Kit (not included)
Is recommended for the following:
Single Injector:
To prevent mineral buildup within the body of the unit. Use when
injecting chemicals that cause minerals to precipitate from  uid
(see Fig. 5)
Injectors In a Series:
When injecting multiple chemical injections, using two or more
injectors. Each injector adds chemical to the  uid(water) system,
while bypassing the next injector and eliminating the potential
damage to that injector (see Fig. 6).
Fig. 6
Remote Injector
NOTE: when mixing more than one chemical, always refer to your
chemical manufacturer information guide for proper application.
Kit shown in a
Contact your local distributor or Dosmatic customer service for
series.
information or to order.

Maintenance

Reference numbers refer to Page 15 - 20
Perform these maintenance
procedures to extend the life of your unit.
Refer to page 17
(2%) Model
Every 3 - 6
Every 6 - 12
Months
months
1. Clean seal areas
1. Replace #17 O-ring
(# 13 & 14).
and #44 Dosage
2. Check #17 O-ring,
Piston.
#37 Cylinder, clean
2. Clean and/or
and/or replace as
replace #13 Check
necessary.
Poppet, #11 Suction
Tube Fitting.
Refer to page 19
(5%) Model
Every 3 - 6
Every 6 - 12
Months
months
1. Clean seal areas
1. Replace #17
(#13).
O-ring and # 52 Shaft
2. Check #17 O-ring,
Assembly.
#37 Cylinder, # 52
2. Clean and/or
Shaft Assembly
replace #13 Check
clean and/or replace
Poppet, #11 Suction
as necessary.
Tube Fitting.
Refer to page 16, 18 & 20
(1%, 2% & 10% Fixed) Models
Every 3 - 6
Every 6 - 12
Months
months
1. Clean seal areas
1. Replace #17 O-ring
(# 13 & 14).
and #44 Dosage Piston.
2. Check #17 O-ring,
Clean and/or replace.
#7 Cylinder, clean
2. #13 Check Poppet ,
and/or replace as
#11 Suction Tube Fitting.
necessary.
Kit Part Numbers
093210
Replace as
necessary
1. #7 Cylinder
2. #14 O-ring
3. #17 O-ring
Replace as
necessary
1. #7 Cylinder
2. #14 O-ring
3. #17 O-ring
Replace as
necessary
1. #7 Cylinder
2. #14 O-ring
3. #17 O-ring

Publicité