Connection - LED2WORK INROLED 70 DC Manuel D'utilisation

Led tube luminaire 24v dc
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5 | Connection

Suitable connection material, cables and accessories can be found in the accessory range of LED2WORK.
The luminaire has to connected via a suitable cable through the end cover with cable gland. The supply cable is connec-
ted to the luminaire via a cable connection and a WAGO terminal.
Connection of the light may only be carried by a qualified electrician!
WAGO connection terminal input:
1. Undo plastic nut of cable connection.
2. After undo the 3 screws of the connection side of luminaire, you can take off the end cover with the cable connection.
3. Insert the connection cable with the open ends.
4. Install cable end according to the dra-wing of this WAGO terminal.
5. After the correct installation, put on the end cover and screw it together again. Pay attention
of a correct seat of the seal and tight the srews handtight only! Do not use an electric
screwdriver!
10 | BA INROLED_70 24V DC . BA 04/2022
Through-wiring (cascadable): Via through-wiring (cascadable) allows the electrical
connection of several luminaires provided for this purpose.
Cascadable: The total current consumption must not exceed 4 A DC at ta +40°C max.
The luminaire is not equipped with a ON/OFF switch. Usually you switch the luminaire ON
or OFF via external switches of machines or systems.

Publicité

Table des Matières
loading

Table des Matières