Husqvarna HMI Manuel D'utilisation page 12

Fs5000 d; fs7000 d; fs7000 dl; fs7000 dmt
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Message on the
Fault code
display
Power supply ex-
C1D0711
ternal device
Power supply ex-
C1D0712
ternal device
C1D0815
AUX1
C1D0811
AUX1
C1D0215
AUX2
C1D0211
AUX2
C1D0315
Blade clutch
C1D0311
Blade clutch
12
DTC description
Circuit short to ground
Circuit short to battery
Circuit short to battery
or open
Circuit short to ground
Circuit short to battery
or open
Circuit short to ground
Circuit short to battery
or open
Circuit short to ground
Indication on the ma-
chine
Cutting can not contin-
ue.
May not be able to
read sensor values.
AUX1 can not be con-
trolled by the HMI.
AUX2 (5th wheel) can
not be controlled by
the HMI.
Blade clutch can not
be controlled by the
HMI.
Blade might be engag-
ed or disengaged the
whole time.
Possible action
Check cables to:
Blade depth sensor and sen-
sor itself E-track position sen-
sor and sensor itself
Neutral start switch and switch
itself
Lower/raise switch and switch
itself
Water safety switch and switch
itself
Check K4 relay in relay/fuse
box.
Check damage to X14 con-
nector, harness to relay/fuse
box and relay/fuse box con-
nector. If found, repair and re-
start system, reset fault code.
If problem still exists, contact
your service agent for further
information.
Check K5 relay in relay/fuse
box.
Check damage to X14 con-
nector, harness to relay/fuse
box and relay/fuse box con-
nector. If found, repair and re-
start system, reset fault code.
If problem still exists, contact
your service agent for further
information.
Check K7 in relay/fuse box.
Check damage to X14 con-
nector, harness to relay/fuse
box and relay/fuse box con-
nector. If found, repair and re-
start system, reset fault code.
If problem still exists, contact
your service agent for further
information.