Installation – Centrifugal Fountain Head
Conversion Kit only (model FPH-05-K01)
Description
The following instructions guide you in converting your aeration pump assembly to a centrifugal fountain assembly. It is
assumed you already have the aeration pump assembly (model number APA-05-HAR) operational and have purchased
the centrifugal fountain conversion kit (model FPH-05-K01). Once completed, the converted fountain pump assembly will
produce several attractive fountain patterns, but aeration to the water will be minimal. However, the unit can always be
converted back to an aeration pump head if desired.
Conversion Process
To watch a video outlining these steps visit our website www.lg-outdoor.com and select the YouTube link.
On your phone, scan the QR code above to visit our YouTube channel.
s
WARNING
!
source before attempting to install, service or remove any component. If the power disconnect is out-of-sight, lock it in the
open position and tag it to prevent unexpected application of power.
Step 1
Ensure all persons are removed from the water.
Step 2
Disconnect electrical power.
a) Turn off power to the pump at the fuse box.
b) Install the lock-out device at the power source.
c) Disconnect the power cord from the outdoor-rated and grounded receptacle.
Step 3
Remove aeration pump/motor assembly from the current application.
a) Disconnect the lanyard to detach the power cord from the float (Figure 2).
b) Lift aeration pump/motor assembly vertically up and remove from float.
c) Take aeration pump/motor assembly to the shore for conversion to decorative fountain.
Leave float anchored/moored in the water.
Step 4
Remove aeration pump head from motor assembly.
a) Place the fountain upright with the motor resting on a stable surface.
CAUTION: Do not allow the unit to fall over as damage may occur.
b) Remove the four indicated bolts that secure the nozzle plate to the motor mount. Clean and store those components
(Figure 4).
c) Remove the propeller from shaft by pulling in an upward motion as the arrow shows. Do not apply excessive force
or damage may occur (Figure 5).
10
RISK OF ELECTRIC SHOCK - Make certain that the unit is disconnected from the power