Installation dimensions

Important note
In order to avoid any problems when installing the appliance and
to avoid damage to the appliance, the following conditions must
be complied with.
The kitchen unit must be aligned horizontally and
vertically!
Minimum wall thickness of the recess = 16 mm.
560 mm - 570 mm
A
min. 550 mm
B
(recommended 560 mm)
1772-1788 mm
C
The positions of the electrical connections are
shown in the technical kitchen manual.
EN-04

Appliance venting

Important note
The clear ventilation cross-
section must be at least
200 cm² from the lower
ventilation opening right to
the upper one.
A
B
C
D
E
Types of air outlet
Directly above the appliance
1
Above the top unit
2
From the front of the top unit with decor grille
3
Important note
When using decor grilles, it must be taken into
account that the clear ventilation cross-section
corresponds to the sum of the individual openings
in the grille.
A cut-out section of merely 200 cm² for installing the
ventilation grille is thus not sufficient.
min. 200 cm²
min. 500 mm
min. 40 mm
min. 500 mm
min. 40 mm