● Installation of gas piping
a. Caution
① Be sure to select a special rubber gas hose or a suitable rigid tube and gas relief valve.
② Select the appropriate tube size according to Table 1.
③ The length of the rubber hose must not exceed 2 meters.
④ The rubber hose must be connected at the red line position of the gas inlet gasket and secured
with a clamp.
⑤ After installation, check with foam for gas leak in the unit.
Connect the unit to the gas joint with a G1 / 2 pipe thread.
b.
When using LPG, connect the gas inlet hose union to the unit gas supply pipe union (make
sure to mount a rubber sealing ring), then connect it with a special gas rubber hose Ф 9.5 mm.
Insert one end into the union of the unit's gas inlet hose until it fits into the red groove in the
union and hold it with a clip.
Installation of water inlet and outlet pipes.
●
Connect the inlet and outlet water pipes and the unit's tap water pipe with a Ф10 mm metal
hose, or with a water pipe with an internal diameter of more than 15 mm.
Water outlet seal
Add a rubber gasket when the metal hose is not used.
Seal
Nut
Water outlet pipe
Junta de tubo de gas
Anillo de sellado de goma
Junta de tubo de manguera
Trabajo de transporte
Manguera de goma para gas
Gas pipe joint
Water inlet pipe gasket
Water inlet pipe
Gas inlet pipe
NOTE
15