MODEL: P
50
LSLW
CLEANING
Avoid using solvents when cleaning plastic parts.
Most plastics are susceptible to damage from
various types of commercial solvents and maybe
damaged by their use. Use clean cloths to remove
dirt, dust , oil, grease, etc.
WARNING:
!
Do not at any time let brake fluids,
gasoline, petroleum-based products,
penetration oils, ect. come in contact with
plastic parts. Chemicals can damage,
weaken or destroy plastic which may
result in serious personal injury.
COLD WEATHER OPERATION
For cold weather operation, near and below
freezing, the moisture in the air line may freeze and
prevent tool operation. We recommend the use of
air tool lubricant or permanent antifreeze (ethylene
glycol) as a cold weather lubricant.
CAUTION:
Do not store tools in a cold weather
environment to prevent frost or ice
formation on the tools' operating valves
and mechanisms that could cause tool
failure.
Quick
coupler
Air hose
Quick
connector
10
.
HTTP://WWW FREEMANTOOLS COM
RECOMMENDED HOOKUP
The air compressor must be able to maintain a
1.
minimum of 70 psi when the tool is being used.
An inadequate air supply can cause a loss of
power and inconsistent driving.
2.
An oiler can be used to provide oil circulation
through the tool. A filter can be used to remove
liquid and solid impurities which can rust or gum
up internal parts of the tool.
3.
Always use air supply hoses with a minimum
working pressure rating equal to or greater than
the pressure from the power source if a
regulator fails, or 150 psi, whichever is greater.
Use 3/8" air hose for runs up to 50' and 3/8"
quick coupler on the air hose.
4.
Use a pressure regulator on the compressor,
with an operating pressure of 0-125 psi. A
pressure regulator is required to control the
operating pressure of the tool between 70 and
115 psi.
CAUTION:
The air compressor must be able to
maintain a minimum of 70psi when the
tool is being used. An inadequate air
supply can cause a loss of power and
inconsistent driving.
WARNING:
!
Do not connect with an air compressor
which can potentially exceed 200psi. As
tool may burst, possibly causing injury.
Quick
Filter
Oiler
connector
Compressor
Quick
Regulator
coupler
.
1-888-669-5672
MODEL: P
50
LSLW
TROUBLESHOOTING
WARNING:
!
Stop using tool immediately if any of the following problems occur. Serious personal injury
could result. Any repairs or replacements must be done by a qualified service person or an
authorized service center.
PROBLEMS
POSSIBLE CAUSES
Air leaking in head cap.
⒈Loose screws.
⒉Worn or damaged O-rings or seals.
Lack of power.
⒈Tool is too dry.
Slow to cycle.
⒉
Air pressure too low.
⒊
Exhaust blocked.
Not shooting fasteners .
⒈Damaged pusher spring.
⒉
Wrong size of fasteners.
Fasteners are
⒈Drive channel is worn.
jammed in the tool
⒉
Piston is broken or worn.
frequently.
⒊
Bent fasteners.
⒋
Dirty magazine.
⒌
Loose magazine.
⒍
Wrong fasteners.
WARNING:
!
Use only Freeman Authorized Repair Parts. For question please call 1-888-669-5672 or visit
our website at http:// www.freemantools.com
WEARING PARTS
Repair parts can be ordered from our website: http://www.freemantools.com
.
HTTP://WWW FREEMANTOOLS COM
CORRECTION ACTIONS
⒈Tighten screws.
⒉
Install overhaul kit.
⒈Add about 2-3 drops of
lubrication into the air connector.
⒉Make sure the air compressor
is set between 70psi and 115psi.
⒊
Clean exhaust channel.
⒈Replace spring.
⒉Use 1/2" crown staples or
1-1/2" to 2"nails.
⒈Fix the drive channel.
⒉
Replace the piston.
⒊
Remove the bent fasteners,
replace with the 1/2"crown
staples or 1-1/2" to 2"nails.
⒋
Clean magazine.
⒌
Tighten screws.
⒍
Verify that fasteners are the
correct size.
.
1-888-669-5672