Page 8
AXIS 233D
As the camera is not yet installed in the housing, this is a preparatory step
showing how to connect the brown cables from the 24V connector to the
8-pin green connector block (supplied with the camera). When the
camera is later installed in the housing, this connector block will then be
connected to the camera itself. Referring to the connection diagram on
the right, connect the brown cables for your version of the T95A.
• AXIS T95A00 Dome Housing (24V DC)
Connect +24V to AC/DC+
Connect -24V to GND/DC-
• AXIS T95A10 Dome Housing (24V AC)
Connect +24V to AC/DC+
Connect -24V to AC.
Prepare the cable gland plate
Fix the 3 cable glands to the cable gland plate and place the cable gland plugs on them. Insert the
four M3 screws through the gasket and plate.
The preparation for the network camera installation is now complete.
AXIS T95A00/T95A10 Dome Housing
AXIS 233D
Connector
AC
AC/DC+
GND/DC-
12V out
GND
Line out
GND
Line/Mic in