Safety engineering

SAFEMASTER STS
Safety switch and key transfer system
POWER INTERLOCKING

Function

Secure disconnection of machines and systems via a load isolator.
Locking of the load isolator in switched-off condition.

Additional Examples

Mechanical
Switch
M10SL1PR40
SX01SLPR40
(Load isolator,
(Load isolator,
front mounting)
front mounting)
All information in the list corresponds to the technical state of the art at the time of printing.
Technical improvements and changes reserved at any time.
Advantages STS-Power Interlocking
• EC Type test certificate according to the Machinery Directive
• For safety applications up to PLe/Cat. 4 according to DIN EN ISO 13849-1
• Coding level low, medium and high according
• It is ensured that the main switch is turned off before a machine can
• Machine is securely disconnected from mains with load isolation and
• Secure locking even if auxiliary and control circuits fail
• The load isolator can be operated at all times with all versions to
• When using frequency converters with STO (Safe Torque Off)
Features
• Up to Performance Level (PL) e and Category 4 according to
• Emergency-off or zone stop
• High switching capacity, currents from 25 A to 800 A (AC23)

Approvals and Marking

*Refers to the components of „Safemaster STS"

Application

With key transfer systems there are two different types of disconnection:
Solenoid locking
Control interlocking
The machine is disconnected via electrical or electronic control for
example, the machine is disconnected via contactors.
Power interlocking
A load isolator must be positively switched over before releasing a key.
This ensures that the machine or system is securely disconnected from
power. This type of disconnection does not depend on auxiliary or control
circuits.
The electrical circuits built into the SAFEMASTER STS Power
Interlocking systems for both tumbler or switch systems, are suitable
for diagnostic monitoring by safety relays in Emergency stop circuits.
Disconnection errors can then be detected and faulty operation can
be prevented. In addition this forms a second channel which ensures
reliable operation in the case of a fault.
The purely mechanical designs do not feature any diagnostic functions.
They can therefore only be employed up to Performance Level (PL) c
max. It is possible by adding additional STS units or Power I=nterlocking
units with integrated electric diagnostic function to achieve Performance
Level (PL) d or (PL) e.
ZRH01SLPR250
(Load isolator,
side mounting)
21
2006/42/EC, Annex IX
to DIN EN ISO 14119:2014-03
be entered.
secured against reclosure, e.g. during repair work.
trigger an emergency stop (Stop 0)
contactors are not required
EN ISO 13849-1
C