Check For Leaks - GE JGP336 Instructions D'installation

Masquer les pouces Voir aussi pour JGP336:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions
C
Installing the Cooktop

Check for Leaks

C5
Check for leaks. After connecting the cooktop
to gas, check system for leaks with a
manometer. If a manometer is not available,
turn the gas supply on to the cooktop and
use a liquid leak detector at all joints and
connections to check for leaks.
Tighten all connections if necessary to
prevent gas leakage in the cooktop or supply
line.
Check alignment of valves after connecting
the cooktop to the gas supply to be sure the
manifold pipe has not been moved. A
misalignment could cause the valve knob
stem to rub on the control panel, resulting
in a gas leak at the valve.
DO NOT USE OPEN FLAME TO CHECK
FOR LEAKS!
Disconnect this cooktop and its individual
shutoff valve from the gas supply piping
system during any pressure testing of that
system at test pressures greater than 1/2"
psig.
Isolate the cooktop from the gas supply
piping system by closing its individual shutoff
valve during any pressure testing of the gas
supply system at test pressures equal to or
less than 1/2" psig.
INSTALLATION OVER
C6
BUILT-IN OVEN
See built-in oven installation for complete
installation instructions.
90°
STREET EL
CABINET SIDES
7
cont.
5" TO CENTER
OF 2" DIA. HOLE
FROM COUNTERTOP
2" DIA. HOLE (20 7/8"
FROM FRONT OF
COUNTERTOP TO
HOLE CENTER)