GCV3412 CODE VALVE INSTALLATION INSTRUCTIONS
Copper Pipe
1. Turn off water supply.
2. Clean pipe, fittings and valve with sandpaper or wire brush.
3. Apply a thin layer of flux to all surfaces to be soldered.
4. Assemble valve to pipe and/or fittings.
5. Cooling the valve by wrapping a wetted rag around the valve is
optional.
6. Heat the joints with a torch. Apply solder to each joint. Continue to
apply heat sufficient to keep solder liquid.
7. After solder has filled entire joint area, remove heat and allow joint
to cool. Do not move or disturb.
8. Slide compression nut over 1/4" copper tube followed by
compression sleeve.
9. Insert tube into valve fully and tighten nut.
10. Turn on water supply and check for leaks.
*CODE VALVE IS INCLUDED WITH AUTOMATIC MODELS ONLY
3/4" TEE
SNSR
7
OUTDOOR TEMP. SENSOR
HUM
WIRE JUMPER
WIRE JUMPER
AC N
AC L
SNSR
OUTDOOR TEMP. SENSOR
HUM
WIRE
JUMPER
AC N
AC L
727-58 24 V. TRANSFORMER
HUMIDISTAT
HUMIDISTAT
24 V. TRANSFORMER
7A-7D Electronic Humidistat
7A - To furnace control board 24 volts
7B - To constant power using 24V transformer and pressure switch
7C - To furnace control board 115 volts with 24V transformer
7D - To constant power using 24V relay and current sensing relay
1/2" TEE
24V. SOLENOID VALVE
FURNACE
CONTROL BOARD
C
W
24v.
60CY.
7A
R
24V. SOLENOID VALVE
W 24v.
N
60CY.
FURNACE
115v.
7C
(HOT)
BOARD
ON-OFF SWITCH
60CY.
24V. SOLENOID VALVE
FURNACE
CONTROL BOARD
C
24v.
60CY.
7E
HUM
24V. SOLENOID VALVE
FURNACE
BOARD
C
115v.
60CY.
(HOT)
7G
ON-OFF SWITCH
ACC
EAC
5
Connect 1/4" water supply tube to brass filter at inlet of solenoid. DO
NOT USE PLASTIC TUBING IN CONTACT WITH ANY HOT
PLENUM SURFACE OR DUCT. IF USING PLASTIC TUBING, USE
TUBE SUPPORT P189 AND PLASTIC COMPRESSION SLEEVE
P190.
6
Turn damper knob to winter (open) position. Turn on water
supply and check operation of humidifier. Set humidistat to a demand
setting. With the furnace off, the solenoid valve should be closed.
Start the furnace, the solenoid valve should open when the blower or
burner circuit is energized. Check flow of water through distributor
trough and evaporator pad. The standard GA4231 yellow orifice will
supply approximately 3.5 GPH of water at a line water pressure of 60
psi. For low water pressures (20-40 psi) a larger orange orifice
GA4299 is available to provide the same flow. Leave humidistat set
at the recommended setting.
Connect drain hose to 1/2" spout on humidifier cabinet using hose
clamp. Run 1/2" hose to suitable drain such as floor drain, sewer or
laundry sink. Be sure hose has continuous slope and is not kinked at
any point.
SNSR
OUTDOOR TEMP. SENSOR
HUM
WIRE
12500 AIR
JUMPER
PRESSURE SWITCH
AC N
AC L
727-58 24 V. TRANSFORMER
24V. SOLENOID VALVE
OUTDOOR TEMP. SENSOR
SNSR
HUM
WIRE
JUMPER
AC N
AC L
ON-OFF SWITCH
727-58 24 V. TRANSFORMER
HUMIDISTAT
NO
C
12500 AIR
24 V. TRANSFORMER
PRESSURE SWITCH
24V. SOLENOID VALVE
HUMIDISTAT
ON-OFF SWITCH
24 V. TRANSFORMER
7E-7H Manual Humidistat
7E - To furnace control board 24 volts
7F - To constant power using 24V transformer and pressure switch
7G - To furnace control board 115 volts with 24V transformer
7H - To constant power using 24V relay and current sensing relay
24V. SOLENOID VALVE
NO
C
L2
115v.
60CY.
(HOT)
ON-OFF SWITCH
L1
FURNACE
C
GA50
COMMON LEAD
CURRENT
HI
SENSING
LO
RELAY
C
115v.
60CY.
(HOT)
24V. SOLENOID VALVE
L2
115v.
60CY.
(HOT)
ON-OFF SWITCH
L1
FURNACE
C
GA50
COMMON LEAD
CURRENT
HI
SENSING
LO
RELAY
C
(HOT)
115v.
60CY.
7B
MULTI
SPEED
BLOWER
MOTOR
7D
7F
MULTI
SPEED
BLOWER
MOTOR
7H

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elite 570900 serieElite 900Elite 1000

Table des Matières