FREQUENCY OF MAINTENANCE AND INSPECTION OPERATIONS
All the apparatuses must undergo the following inspections
COMPONENTS
Mask
Full SCBA
COMPONENTS
Mask
Demand valve
Pressure reducer
Compressed air
cylinder
Cylinder valve
X)
1)
2)
3)
4)
Note: For more information about the composition of kits, see the spare parts price list or contact HONEYWELL RESPIRATORY
SAFETY PRODUCTS.
Inspect the apparatus fully (working and sealing) after each change of spare parts.
Some parts have screws sealed using red varnish to certify that the parts were fitted at
HONEYWELL RESPIRATORY SAFETY PRODUCTS. The manufacturer is not liable for incorrect
operation of any part that no longer bears this seal.
Type of work required
Clean and disinfect
(See mask's instructions for use)
Cleaning
Test on bench
User function check
Type of work to be done by a
specialised maintenance
workshop
Replace:
- inhalation/exhalation valves
- seals
Replace:
- diaphragm
- spring
- valve
Replace:
- seal
- piston
Replacement of the high pressure
connector seal
Regular inspection and
requalification by an approved
body
Replace:
- seal
- closure member
Replace:
- Break seal
Required
For frequently-used apparatus
After use in aggressive environments or extreme conditions
For reserve stocks
Not if the apparatus is hermetically packaged
Before
After
use
use
X
X
X(2)
X
X
Every
Every 2
year
years
X
X
Refer to and follow the national regulations
applicable to compressed air reserves
Once every 5 years or more often
At least once every 12 months
EN-6
Every
Every
six
year
months
X(3)
X(4)
X(1)
X
Every 6
Every 10
years
years
X(3)
X (1)
X
X (1)
X