Operating Instructions and Parts Manual
Troubleshooting Guide
SYMPTOM
Low pressure and /or pump
runs rough
Water leakage from under
pump manifold
Water in pump crankcase
(milky oil)
Frequent or premature failure
of the pump water seals
Strong surging at the inlet and
low pressure
Oil leakage between the
engine and the pump
Fluctuating pressure
Pressure drops after period of
normal use
10
POSSIBLE CAUSE(S)
1. Worn or wrong size/type of nozzle
2. Inlet filter on pump clogged
3. Worn water seals, abrasives in water,
or natural wear
4. Fouled or dirty inlet or discharge
valves
5. Restricted inlet
6. Worn inlet or discharge valves
7. Leaking high pressure hose
8. Pump drawing in air
9. Unloader valve seat faulty or worn
Worn water seals
1. Humid air condensing inside
crankcase
2. Oil seals leaking
1. Scored damaged or worn plungers
2. Abrasive material in the fluid
3. Inlet water temperature too high
4. Overpressurizing pump
5. Excessive pressure due to partially
plugged or damaged nozzle
6. Pump running too long without
spraying
7. Pump running dry
Foreign particles in the inlet or discharge
valve or worn inlet and/or discharge
valves
Worn oil seals and/or o-ring
1. Valve worn, dirty or stuck
2. Pump drawing in air
3. Nozzle clogged
1. Worn pump water seals
2. Nozzle worn
3. Valve worn, dirty or stuck
4. Unloader valve seat worn or dirty
www.campbellhausfeld.com
CORRECTIVE ACTION
1. Replace with nozzle of proper size
2. Clean. Check more frequently
3. Check filter. Replace water seals. See service
center
4. Clean inlet and discharge valve assemblies. Check
filter
5. Check garden hose, may be collapsed or kinked.
Check inlet water flow
6. Replace worn valves
7. Replace high pressure hose
8. Ensure hoses and fittings are tight
9. Check and replace
Install new water seals. See AR pump service center
1. Change oil as specified in maintenance schedule
2. Install new oil seals. See AR pump service center
1. Install new plungers. See AR pump service center
2. Install proper filtration on pump inlet plumbing
3. Check water temperature; may not exceed 100° F.
4. Do not modify any factory set adjustments.
5. Clean or replace nozzle.
6. Never run pump more than 1 minute without
spraying
7. Do not run pump without water
Clean or replace valves. See AR pump service center
Replace oil seals and/or o-ring. See service center
1. Discharge or check and replace
2. Ensure hoses and fittings are tight. Purge air from
garden hose
3. Check or replace
1. Check and replace
2. Check and replace
3. Discharge or Check, clean or replace
4. Check, clean or replace
Continued on next page