4.3 Connecting the proportional directional control valve
The valve connection provides the power supply for the
valve and provides the control voltage for the slide valve
setting.
Please note
Use only the original type KMPYE−... cable.
Pin assignment and wire colours for the
KMPYE−... cable
2: 0 V
3: 0 V
4: Setpoint voltage U(s)
5: GND
6: n.c., not connected
7: 24 V supply to valve
1: 24 V supply to valve
n.c, not connected
20
POWER
ERROR
OUT
IN
VALVE
brown
green
yellow
grey
pink
white
blue
red
6
5
7
4
1
3
2
Socket for (MPYE)
valve on the
KMPYE−... cable
2
2
3
4
n.c.
1
n.c.
1
Festo SPC−AIF−... 0506b English