Product Description; Approvals And Markings; Function - DOLD SX01A Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Technique
SAFEMASTER STS
Safety Switch- and Key Interlock System
Basic Unit SX01A, SX01BM
SX01A
Presentation in the deactivated condition:
Key and actuator removed

Product Description

Switch with separate actuator and forced key removal
When the key is removed, the contacts switch and the actuator is released.
For the key exchange and duplication with mechanical securing of
separating guards such as safety gates and hoods in machine and plant
engineering.
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
STS-System Benefits
• EU-Test certificate according to the directive 2006/42/EG, annex IX
• For safety applications up to PLe / Cat. 4 acc. to DIN EN ISO 13849-1
• Modular and expandable system
• Rugged stainless steel design
• Wireless mechanical safeguarding
• Combines the benefits of safety switch, solenoid locking and
key transfer in a single system
• Easy installation through comprehensive accessories
• Protection against lock-in
• Coding level low, medium, high according to DIN EN ISO 14119:2014-03
Features
The unit is particularly suitable for applications with:
• Several mechanically secured entries
• Extremely rugged ambient conditions
• Required feed back signal of the key
• Required access rights
SX01BM

Approvals and Markings

Function

With the SX01A version, actuators can be inserted both laterally and
from above into the actuator module. The coding level of the associated
actuators according to EN ISO 14119:2013 is low.
The SX01BM version offers increased stability of the actuator module.
It is also available in accordance with EN ISO14119:2013 with actuators
for low and medium coding levels.
The key can be used as part of a key transfer system or as a person-
al key, i.e. as protection against confinement and unexpected restart.
Multiple keys make it possible to operate several units in the system or
to protect several people. For this purpose, the SX01BM unit can also
be extended above the actuator module with additional key modules. By
using personal Key normally no escape release (ISO TS19837:2017)
is required.
Both versions can optionally be equipped with padlock modules and man-
ual unlocking. Switch modules with disable function have the designation
SV module.This unit can be connected to the SAFEMASTER STS option
module, which contains command functions and is designed for wiring
cross-sections up to 1.5mm
19
C
US
2
.
SAFEMASTER STS-SX01A, SX01BM / 23.09.19 en / 135A