Electrical Installation/Automatic Mode
In selecting the wiring leads, it
is important to meet the wiring
regulations laid down in VDE
0100 (see Safety Precautions on
page 4). The following applies
to wiring presence detectors:
According to section 6 of
VDE 0100 520, a multiple-core
lead containing both the mains
voltage leads and the control
leads (e.g. NYM 5 x 1.52) may
be used for wiring between the
sensor and electronic ballast.
The mains connection cable
must be no greater than 10 mm
in diameter. The clamping range
- 11 -
of the mains terminal is de-
signed for a maximum of
2
2
2 x 1.5 mm
or 1 x 2.5 mm
.