3. Safe POSiTiOninG
• Only ever use the appliance in an upright position WITH kNOBS ON THE TOP.
• When portable, always maintain a distance of at least 1m between the product and any inflammable
object/surface.
• When the product is wall mounted, make sure that the minimum distances reported in pictures 1 and 2
are respected. Do not place the heater so that the air flow blows directly towards the wall.
• As the heater is a class 2 product, earth connection is not required.
• The heater has an IPX1 protection level against water and, if wall mounted may be installed in bathrooms.
In any case you have to respect the national installation standard and safety requirements valid in your State.
• Never install/use this appliance in the Zones 0, 1 or 2 illustrated in picture 3:
• On no account must any switch / button be accessible by people in the shower or in the bathtub.
4. WaLL MOunTinG (TL-29W / TL-29 TW)
After carefully reading section 3, proceed with installation following the sequence shown in picture 4.
To hang on the product proceed as follows:
• Lay the base of the product on the base of the wall bracket coupling the plastic ribs created to make
the lodging easier;
• Push a little bit the product downwards and move the upper side of the product near the bracket;
• Check that the upper holed rib of the bracket fits the dedicated pivot created on the back grid of the
heater. Moderately shake the heater after installation to be sure it is correctly fixed
To release the product from the bracket proceed as follows:
• Use your hand to push downwards the upper rib of the bracket as much as necessary to release the
product by pulling it on the top.
• Once the product has been unlocked on the upper side just pull it upwards to release it from its base.
IMPORTANT FOR FRANCE:
If the product is wall mounted, the electrical connection must be made according to the enclosed drawing,
cutting the cable and using a connection block between the product cable and the electricity supply.
Electricity
In humid rooms, bathrooms or kitchens, this connection block must be installed at least 25 cm from the floor. The
electrical connection must also include the use of a 2-pole switch with a contact opening distance of at least 3 mm.
2
1
Phase = brown
L
N
Neutral = blue
4
3
click!
9
Product's cable

Publicité