Always disconnect the appliance from the electrical power source before
making any adjustments. All seals must be replaced by the technician
when any adjustments are completed.
Taps
"Reduced rate" adjustment:
1. Switch on the burner and turn the relative knob to the "Reduced rate" position
(small flame fig. 8 page 11).
2. Remove knob "M" (fig. 6 and 6/A) of the tap, which is simply pressed on to its
rod.
3. The by-pass for minimal rate regulation can be: beside the tap (fig. 6) or
inside the shaft. In any case, to access the regulation, it can be done through
the insertion of a small screwdriver ''D'' beside the tap (fig. 6) or in the hole
''C'' inside the shaft of the tap (fig 6/A).
Turn the throttle screw to the right or left until the burner flame has been
adequately regulated to the "Reduced rate" position.
The flame should not be too low: the lowest small flame should be continuous
and steady. Re-assemble the several components.It is understood that only
burners operating with Natural Gas or City Gas should be subjected to the
above-mentioned adjustments. The screw must be fully locked when the
burners operate with Propane (turn clockwise).
The operations described above can be carried out easily, whatever the position
of the cooktop or however it is fastened to the work surface.
THE BURNERS DO NOT REQUIRE ANY REGULATION OF INCOMING AIR.
FIG. 6
ADJUSTMENTS
9
FIG. 6/A